Mitigation of partial volume effects in susceptibility‐based oxygenation measurements by joint utilization of magnitude and phase (JUMP). Issue 4 (5th April 2016)
- Record Type:
- Journal Article
- Title:
- Mitigation of partial volume effects in susceptibility‐based oxygenation measurements by joint utilization of magnitude and phase (JUMP). Issue 4 (5th April 2016)
- Main Title:
- Mitigation of partial volume effects in susceptibility‐based oxygenation measurements by joint utilization of magnitude and phase (JUMP)
- Authors:
- McDaniel, Patrick
Bilgic, Berkin
Fan, Audrey P.
Stout, Jeffrey N.
Adalsteinsson, Elfar - Abstract:
- Abstract : Purpose: Susceptibility‐based blood oxygenation measurements in small vessels of the brain derive from gradient echo (GRE) phase and can provide localized assessment of brain function and pathology. However, when vessel diameter becomes smaller than the acquisition voxel size, partial volume effects compromise these measurements. The purpose of this study was to develop a technique to improve the reliability of vessel oxygenation estimates in the presence of partial volume effects. Methods: Intravoxel susceptibility variations are present when a vessel and parenchyma experience partial volume effects, modifying the voxel's GRE phase signal and attenuating the GRE magnitude signal. Using joint utilization of magnitude and phase (JUMP), both vessel susceptibility and voxel partial volume fraction can be estimated, providing measurements of venous oxygen saturation ( Y v ) in straight, nearly vertical vessels that have improved robustness to partial volume effects. Results: JUMP was demonstrated by estimating vessel Y v in numerical and in vivo experiments. Deviations from ground truth of Y v measurements in vessels tilted up to 30° from B 0 were reduced by over 50% when using JUMP compared with phase‐only techniques. Conclusion: JUMP exploits both magnitude and phase data in GRE imaging to mitigate partial volume effects in estimation of vessel oxygenation. Magn Reson Med 77:1713–1727, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 4(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 4(2017)
- Issue Display:
- Volume 77, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 4
- Issue Sort Value:
- 2017-0077-0004-0000
- Page Start:
- 1713
- Page End:
- 1727
- Publication Date:
- 2016-04-05
- Subjects:
- susceptibility‐weighted imaging -- oxygenation -- partial volume effects -- quantitative susceptibility mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26227 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1626.xml