When are bacteria dead? A step towards interpreting flow cytometry profiles after chlorine disinfection and membrane integrity staining. Issue 7 (3rd April 2017)
- Record Type:
- Journal Article
- Title:
- When are bacteria dead? A step towards interpreting flow cytometry profiles after chlorine disinfection and membrane integrity staining. Issue 7 (3rd April 2017)
- Main Title:
- When are bacteria dead? A step towards interpreting flow cytometry profiles after chlorine disinfection and membrane integrity staining
- Authors:
- Nocker, Andreas
Cheswick, Ryan
Dutheil de la Rochere, Pierre-Marie
Denis, Matthieu
Léziart, Tangui
Jarvis, Peter - Abstract:
- ABSTRACT: Flow cytometry is increasingly employed by drinking water providers. Its use with appropriate fluorescent stains allows the distinction between intact and membrane-damaged bacteria, which makes it ideally suited for assessment of disinfection efficiency. In contrast to plate counting, the technology allows the visualization of the gradual loss of membrane integrity. Although this sensitivity per se is very positive, it creates the problem of how this detailed viability information compares with binary plate counts where a colony is either formed or not. Guidelines are therefore needed to facilitate interpretation of flow cytometry results and to determine a degree of membrane damage where bacteria can be considered 'dead'. In this study we subjected Escherichia coli and environmental microorganisms in real water to increasing chlorine concentrations. Resulting flow cytometric patterns after membrane integrity staining were compared with culturability and in part with redox activity. For laboratory-grown bacteria, culturability was lost at lower disinfectant concentrations than membrane integrity making the latter a conservative viability parameter. No recovery from chlorine was observed for four days. For real water, loss of membrane integrity had to be much more substantial to completely suppress colony formation, probably due to the heterogenic composition of the natural microbial community with different members having different susceptibilities to theABSTRACT: Flow cytometry is increasingly employed by drinking water providers. Its use with appropriate fluorescent stains allows the distinction between intact and membrane-damaged bacteria, which makes it ideally suited for assessment of disinfection efficiency. In contrast to plate counting, the technology allows the visualization of the gradual loss of membrane integrity. Although this sensitivity per se is very positive, it creates the problem of how this detailed viability information compares with binary plate counts where a colony is either formed or not. Guidelines are therefore needed to facilitate interpretation of flow cytometry results and to determine a degree of membrane damage where bacteria can be considered 'dead'. In this study we subjected Escherichia coli and environmental microorganisms in real water to increasing chlorine concentrations. Resulting flow cytometric patterns after membrane integrity staining were compared with culturability and in part with redox activity. For laboratory-grown bacteria, culturability was lost at lower disinfectant concentrations than membrane integrity making the latter a conservative viability parameter. No recovery from chlorine was observed for four days. For real water, loss of membrane integrity had to be much more substantial to completely suppress colony formation, probably due to the heterogenic composition of the natural microbial community with different members having different susceptibilities to the disinfectant. … (more)
- Is Part Of:
- Environmental technology. Volume 38:Issue 7(2017)
- Journal:
- Environmental technology
- Issue:
- Volume 38:Issue 7(2017)
- Issue Display:
- Volume 38, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 38
- Issue:
- 7
- Issue Sort Value:
- 2017-0038-0007-0000
- Page Start:
- 891
- Page End:
- 900
- Publication Date:
- 2017-04-03
- Subjects:
- Bacteria -- chlorine disinfection -- viability -- flow cytometry -- live–dead staining -- survival
Environmental engineering -- Periodicals
Environmental protection -- Periodicals
628.05 - Journal URLs:
- http://www.tandfonline.com/toc/tent20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/09593330.2016.1262463 ↗
- Languages:
- English
- ISSNs:
- 0959-3330
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.698800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: