The impact of sphincterotome design on selective cannulation of the common bile duct. Issue 9 (22nd August 2013)
- Record Type:
- Journal Article
- Title:
- The impact of sphincterotome design on selective cannulation of the common bile duct. Issue 9 (22nd August 2013)
- Main Title:
- The impact of sphincterotome design on selective cannulation of the common bile duct
- Authors:
- Ozaslan, Ersan
Ozaslan, Nihal Gokbulut
Purnak, Tugrul
Ozkaya, Guven - Abstract:
- Abstract: Background and Aim: There is a paucity of data regarding the impact of sphincterotome design on cannulation success. Methods: We aimed to compare the 5.5 F standard sphincterotomes of two different manufacturers (sphincterotome 1: Endo‐flex 5.5F [ENDO‐FLEX GmbH, Voerde, Düsseldorf, Germany] vs sphincterotome 2: Ultratome 5.5F [Boston Scientific, Spencer, IN, USA]). Adult patients undergoing their first endoscopic retrograde cholangiopancreatography were included in two study groups. The sphincterotome preloaded with a guidewire was used for selective common bile duct cannulation in each group. Precut methods were applied in failed cases without crossover. Successful biliary cannulation in 10 attempts was the primary outcome. Results: Baseline features and indications were similar between groups ( n = 100, group I, sphincterotome 1, vs n = 100, group II, sphincterotome 2). A higher success in initial cannulation was obtained in group II compared to group I (92% vs 81%, P = 0.03). Moreover, number of cannulation attempts and time to cannulation differed. No statistical significance was noted in group I (8%) versus group II (3%) regarding pancreatitis rate. The overall cannulation success after precut in failed cases was 95% (group I) and 97% (group II). Conclusions: There was a significant difference in cannulation success between the two different sphincterotome. 5.5F Ultratome with guidewire was superior to 5.5F Endo‐flex sphincterotome with guidewire in initialAbstract: Background and Aim: There is a paucity of data regarding the impact of sphincterotome design on cannulation success. Methods: We aimed to compare the 5.5 F standard sphincterotomes of two different manufacturers (sphincterotome 1: Endo‐flex 5.5F [ENDO‐FLEX GmbH, Voerde, Düsseldorf, Germany] vs sphincterotome 2: Ultratome 5.5F [Boston Scientific, Spencer, IN, USA]). Adult patients undergoing their first endoscopic retrograde cholangiopancreatography were included in two study groups. The sphincterotome preloaded with a guidewire was used for selective common bile duct cannulation in each group. Precut methods were applied in failed cases without crossover. Successful biliary cannulation in 10 attempts was the primary outcome. Results: Baseline features and indications were similar between groups ( n = 100, group I, sphincterotome 1, vs n = 100, group II, sphincterotome 2). A higher success in initial cannulation was obtained in group II compared to group I (92% vs 81%, P = 0.03). Moreover, number of cannulation attempts and time to cannulation differed. No statistical significance was noted in group I (8%) versus group II (3%) regarding pancreatitis rate. The overall cannulation success after precut in failed cases was 95% (group I) and 97% (group II). Conclusions: There was a significant difference in cannulation success between the two different sphincterotome. 5.5F Ultratome with guidewire was superior to 5.5F Endo‐flex sphincterotome with guidewire in initial selective cannulation of common bile duct. The results may show the importance of sphincterotome features to overcome the obstacles during cannulation such as complex intrapapillary mucosal features. … (more)
- Is Part Of:
- Journal of gastroenterology and hepatology. Volume 28:Issue 9(2013:Sep.)
- Journal:
- Journal of gastroenterology and hepatology
- Issue:
- Volume 28:Issue 9(2013:Sep.)
- Issue Display:
- Volume 28, Issue 9 (2013)
- Year:
- 2013
- Volume:
- 28
- Issue:
- 9
- Issue Sort Value:
- 2013-0028-0009-0000
- Page Start:
- 1573
- Page End:
- 1577
- Publication Date:
- 2013-08-22
- Subjects:
- cannulation -- ERCP -- sphincterotome
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Liver Diseases -- Periodicals
616.33 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1440-1746 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jgh ↗ - DOI:
- 10.1111/jgh.12210 ↗
- Languages:
- English
- ISSNs:
- 0815-9319
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4987.615000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1079.xml