The microINR portable coagulometer: analytical quality and user-friendliness of a PT (INR) point-of-care instrument. (17th February 2017)
- Record Type:
- Journal Article
- Title:
- The microINR portable coagulometer: analytical quality and user-friendliness of a PT (INR) point-of-care instrument. (17th February 2017)
- Main Title:
- The microINR portable coagulometer: analytical quality and user-friendliness of a PT (INR) point-of-care instrument
- Authors:
- Larsen, Pia Bükmann
Storjord, Elin
Bakke, Åsne
Bukve, Tone
Christensen, Mikael
Eikeland, Joakim
Haugen, Vegar Engeland
Husby, Kristin
McGrail, Rie
Mikaelsen, Solveig Meier
Monsen, Grete
Møller, Mette Fogh
Nybo, Jan
Revsholm, Jesper
Risøy, Aslaug Johanne
Skålsvik, Unni Marie
Strand, Heidi
Teruel, Reyes Serrano
Theodorsson, Elvar - Abstract:
- Abstract: Regular measurement of prothrombin time as an international normalized ratio PT (INR) is mandatory for optimal and safe use of warfarin. Scandinavian evaluation of laboratory equipment for primary health care (SKUP) evaluated the microINR portable coagulometer (microINR ® ) (iLine Microsystems S.L., Spain) for measurement of PT (INR). Analytical quality and user-friendliness were evaluated under optimal conditions at an accredited hospital laboratory and at two primary health care centres (PHCCs). Patients were recruited at the outpatient clinic of the Laboratory of Medical Biochemistry, St Olav's University Hospital, Trondheim, Norway ( n = 98) and from two PHCCs ( n = 88). Venous blood samples were analyzed under optimal conditions on the STA-R ® Evolution with STA-SPA + reagent (Stago, France) (Owren method), and the results were compared to capillary measurements on the microINR ® . The imprecision of the microINR ® was 6% (90% CI: 5.3–7.0%) and 6.3% (90% CI: 5.1–8.3) in the outpatient clinic and PHCC2, respectively for INR ≥2.5. The microINR ® did not meet the SKUP quality requirement for imprecision ≤5.0%. For INR <2.5 at PHCC2 and at both levels in PHCC1, CV% was ≤5.0. The accuracy fulfilled the SKUP quality goal in both outpatient clinic and PHCCs. User-friendliness of the operation manual was rated as intermediate, defined by SKUP as neutral ratings assessed as neither good nor bad. Operation facilities was rated unsatisfactory, and time factorsAbstract: Regular measurement of prothrombin time as an international normalized ratio PT (INR) is mandatory for optimal and safe use of warfarin. Scandinavian evaluation of laboratory equipment for primary health care (SKUP) evaluated the microINR portable coagulometer (microINR ® ) (iLine Microsystems S.L., Spain) for measurement of PT (INR). Analytical quality and user-friendliness were evaluated under optimal conditions at an accredited hospital laboratory and at two primary health care centres (PHCCs). Patients were recruited at the outpatient clinic of the Laboratory of Medical Biochemistry, St Olav's University Hospital, Trondheim, Norway ( n = 98) and from two PHCCs ( n = 88). Venous blood samples were analyzed under optimal conditions on the STA-R ® Evolution with STA-SPA + reagent (Stago, France) (Owren method), and the results were compared to capillary measurements on the microINR ® . The imprecision of the microINR ® was 6% (90% CI: 5.3–7.0%) and 6.3% (90% CI: 5.1–8.3) in the outpatient clinic and PHCC2, respectively for INR ≥2.5. The microINR ® did not meet the SKUP quality requirement for imprecision ≤5.0%. For INR <2.5 at PHCC2 and at both levels in PHCC1, CV% was ≤5.0. The accuracy fulfilled the SKUP quality goal in both outpatient clinic and PHCCs. User-friendliness of the operation manual was rated as intermediate, defined by SKUP as neutral ratings assessed as neither good nor bad. Operation facilities was rated unsatisfactory, and time factors satisfactory. In conclusion, quality requirements for imprecision were not met. The SKUP criteria for accuracy was fulfilled both at the hospital and at the PHCCs. The user-friendliness was rated intermediate. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 77:Number 2(2017)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 77:Number 2(2017)
- Issue Display:
- Volume 77, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 2
- Issue Sort Value:
- 2017-0077-0002-0000
- Page Start:
- 115
- Page End:
- 121
- Publication Date:
- 2017-02-17
- Subjects:
- International normalized ratio -- point-of-care systems -- point-of-care testing -- quality control -- warfarin
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2016.1277433 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1125.xml