Evaluation of the activated partial thromboplastin time assay for clinical monitoring of PEGylated recombinant factor VIII (BAY 94‐9027) for haemophilia A. (29th January 2014)
- Record Type:
- Journal Article
- Title:
- Evaluation of the activated partial thromboplastin time assay for clinical monitoring of PEGylated recombinant factor VIII (BAY 94‐9027) for haemophilia A. (29th January 2014)
- Main Title:
- Evaluation of the activated partial thromboplastin time assay for clinical monitoring of PEGylated recombinant factor VIII (BAY 94‐9027) for haemophilia A
- Authors:
- Gu, J‐M.
Ramsey, P.
Evans, V.
Tang, L.
Apeler, H.
Leong, L.
Murphy, J. E.
Laux, V.
Myles, T. - Abstract:
- Summary: Patients with haemophilia (PWH) are usually monitored by the one‐stage activated partial thromboplastin time (aPTT) factor VIII (FVIII) assay. Different aPTT activators may affect clotting time (CT) and FVIII:C levels in patients treated with PEGylated FVIII. To evaluate the characteristics of PEGylated FVIII (BAY 94‐9027) in various aPTT clotting assays, and to identify suitable aPTT reagents for monitoring BAY 94‐9027 during the treatment of PWH, BAY 94‐9027 and World Health Organization (WHO) 8th FVIII standards (WHO‐8) were spiked into pooled and individual severe haemophilia A plasma at 1.0, 0.25 and 0.05 IU mL −1 . Five commercial aPTT reagents widely used in clinical laboratories were compared and evaluated for BAY 94‐9027 activity in plasma from PWH. BAY 94‐9027 and WHO‐8 bestowed similar CT and excellent precision when ellagic acid (SynthAFax, Dade Actin, and Cephascreen) aPTT reagents were used. In contrast, BAY 94‐9027 showed significantly prolonged CT and poor precision compared with WHO‐8 using silica aPTT reagents (APTT‐SP and STA PTT 5). Furthermore, free 60‐kDa polyethylene glycol (PEG), used for the conjugation of FVIII, showed a dose‐dependent prolongation of CT in the APTT‐SP assay. There was no effect on the SynthAFax‐APTT, prothrombin time, or FXIa‐initiated thrombin generation assay, demonstrating that the PEG moiety on FVIII has no general effect on the coagulation cascade. In summary, ellagic aPTT reagents (SynthAFax, Dade Actin, andSummary: Patients with haemophilia (PWH) are usually monitored by the one‐stage activated partial thromboplastin time (aPTT) factor VIII (FVIII) assay. Different aPTT activators may affect clotting time (CT) and FVIII:C levels in patients treated with PEGylated FVIII. To evaluate the characteristics of PEGylated FVIII (BAY 94‐9027) in various aPTT clotting assays, and to identify suitable aPTT reagents for monitoring BAY 94‐9027 during the treatment of PWH, BAY 94‐9027 and World Health Organization (WHO) 8th FVIII standards (WHO‐8) were spiked into pooled and individual severe haemophilia A plasma at 1.0, 0.25 and 0.05 IU mL −1 . Five commercial aPTT reagents widely used in clinical laboratories were compared and evaluated for BAY 94‐9027 activity in plasma from PWH. BAY 94‐9027 and WHO‐8 bestowed similar CT and excellent precision when ellagic acid (SynthAFax, Dade Actin, and Cephascreen) aPTT reagents were used. In contrast, BAY 94‐9027 showed significantly prolonged CT and poor precision compared with WHO‐8 using silica aPTT reagents (APTT‐SP and STA PTT 5). Furthermore, free 60‐kDa polyethylene glycol (PEG), used for the conjugation of FVIII, showed a dose‐dependent prolongation of CT in the APTT‐SP assay. There was no effect on the SynthAFax‐APTT, prothrombin time, or FXIa‐initiated thrombin generation assay, demonstrating that the PEG moiety on FVIII has no general effect on the coagulation cascade. In summary, ellagic aPTT reagents (SynthAFax, Dade Actin, and Cephascreen) are most suitable for evaluating potency of BAY 94‐9027 and should be the preferred aPTT reagents used in clinical laboratories for monitoring FVIII activity after infusion of BAY 94‐9027 to PWH. … (more)
- Is Part Of:
- Haemophilia. Volume 20:Number 4(2014:Jul.)
- Journal:
- Haemophilia
- Issue:
- Volume 20:Number 4(2014:Jul.)
- Issue Display:
- Volume 20, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2014-0020-0004-0000
- Page Start:
- 593
- Page End:
- 600
- Publication Date:
- 2014-01-29
- Subjects:
- aPTT assays -- clotting time -- coagulation tests -- factor VIII -- haemophilia -- PEGylation
Hemophilia -- Periodicals
616.1572005 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=hae ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2516 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/hae.12374 ↗
- Languages:
- English
- ISSNs:
- 1351-8216
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4238.086500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2559.xml