Clinical Evaluation of Rigid Gas Permeable Contact Lenses and Visual Outcome After Repaired Corneal Laceration. Issue 1 (January 2015)
- Record Type:
- Journal Article
- Title:
- Clinical Evaluation of Rigid Gas Permeable Contact Lenses and Visual Outcome After Repaired Corneal Laceration. Issue 1 (January 2015)
- Main Title:
- Clinical Evaluation of Rigid Gas Permeable Contact Lenses and Visual Outcome After Repaired Corneal Laceration
- Authors:
- Zheng, Bin
Shen, Lijun
Walker, Maria K.
Zhang, Zongduan
Zheng, Jingwei
She, Xiangjun
Zhou, Jing
Xu, Zhaoxia
Chen, Yan - Abstract:
- Abstract : Objective: To evaluate the clinical value of rigid gas permeable contact lenses (RGPCLs) in patients with traumatic corneal scarring and address implications of primary corneal repair. Methods: Eighteen subjects with a history of corneal laceration were fit with RGPCLs. Scar locations were divided into two zones; each patient was examined using Pentacam. Entering data included uncorrected visual acuity (UCVA), spectacle-corrected visual acuity (SVA), time between injury and RGPCL fitting, location and size of scar, and amount of corneal astigmatism. Follow-up data included RGPCL visual acuity (RGPCLVA), RGPCL-related complications, and dropout characteristics. Visual acuity values were converted to logMAR for analysis. Results: No serious complications occurred. The average time between suture removal and RGPCL fitting was 5.7±5.5 months. Average corneal astigmatism was −3.44±2.09 diopters. One subject had developed corneal ectasia. RGPCLVA was more than 0.1 in three subjects: one experienced primary corneal repair complications, and two subjects (<10 years) developed amblyopia. In both zones, the difference in RGPCLVA outcome between zone I and zone II was not statistically significant (F=0.060, P =0.809). The difference between SVA in zones I and II was found to be statistically significant (F=6.131, P =0.026), as were the differences between SVA and RGPCLVA (F=8.598, P =0.010). The scar size had no significant influence on RGPCLVA, SVA, or UCVA. FourAbstract : Objective: To evaluate the clinical value of rigid gas permeable contact lenses (RGPCLs) in patients with traumatic corneal scarring and address implications of primary corneal repair. Methods: Eighteen subjects with a history of corneal laceration were fit with RGPCLs. Scar locations were divided into two zones; each patient was examined using Pentacam. Entering data included uncorrected visual acuity (UCVA), spectacle-corrected visual acuity (SVA), time between injury and RGPCL fitting, location and size of scar, and amount of corneal astigmatism. Follow-up data included RGPCL visual acuity (RGPCLVA), RGPCL-related complications, and dropout characteristics. Visual acuity values were converted to logMAR for analysis. Results: No serious complications occurred. The average time between suture removal and RGPCL fitting was 5.7±5.5 months. Average corneal astigmatism was −3.44±2.09 diopters. One subject had developed corneal ectasia. RGPCLVA was more than 0.1 in three subjects: one experienced primary corneal repair complications, and two subjects (<10 years) developed amblyopia. In both zones, the difference in RGPCLVA outcome between zone I and zone II was not statistically significant (F=0.060, P =0.809). The difference between SVA in zones I and II was found to be statistically significant (F=6.131, P =0.026), as were the differences between SVA and RGPCLVA (F=8.598, P =0.010). The scar size had no significant influence on RGPCLVA, SVA, or UCVA. Four participants (22.2%) were successfully fit. Dropout characteristics included ocular discomfort, inconvenience, parental apprehension, and low motivation. Conclusions: Rigid gas permeable contact lens is an ideal method for evaluating visual potential in patients with traumatic corneal astigmatism. Pentacam examinations of those patients with poor RGPCLVA can help an ophthalmologist find and understand existing problems in suture techniques. … (more)
- Is Part Of:
- Eye & contact lens. Volume 41:Issue 1(2015:Jan.)
- Journal:
- Eye & contact lens
- Issue:
- Volume 41:Issue 1(2015:Jan.)
- Issue Display:
- Volume 41, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2015-0041-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-01
- Subjects:
- Corneal laceration -- Irregular corneal astigmatism -- Rigid gas permeable contact lenses -- Pentacam -- Corneal ectasia
Contact lenses -- Periodicals
Intraocular lenses -- Periodicals
Orthokeratology -- Periodicals
Anterior segment (Eye) -- Diseases -- Periodicals
617.7523 - Journal URLs:
- http://journals.lww.com/claojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICL.0000000000000061 ↗
- Languages:
- English
- ISSNs:
- 1542-2321
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3854.587000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2178.xml