Levey-Jennings Analysis Uncovers Unsuspected Causes of Immunohistochemistry Stain Variability. Issue 10 (November 2016)
- Record Type:
- Journal Article
- Title:
- Levey-Jennings Analysis Uncovers Unsuspected Causes of Immunohistochemistry Stain Variability. Issue 10 (November 2016)
- Main Title:
- Levey-Jennings Analysis Uncovers Unsuspected Causes of Immunohistochemistry Stain Variability
- Authors:
- Vani, Kodela
Sompuram, Seshi R.
Naber, Stephen P.
Goldsmith, Jeffrey D.
Fulton, Regan
Bogen, Steven A. - Abstract:
- Abstract : Almost all clinical laboratory tests use objective, quantitative measures of quality control (QC), incorporating Levey-Jennings analysis and Westgard rules. Clinical immunohistochemistry (IHC) testing, in contrast, relies on subjective, qualitative QC review. The consequences of using Levey-Jennings analysis for QC assessment in clinical IHC testing are not known. To investigate this question, we conducted a 1- to 2-month pilot test wherein the QC for either human epidermal growth factor receptor 2 (HER-2) or progesterone receptor (PR) in 3 clinical IHC laboratories was quantified and analyzed with Levey-Jennings graphs. Moreover, conventional tissue controls were supplemented with a new QC comprised of HER-2 or PR peptide antigens coupled onto 8 μm glass beads. At institution 1, this more stringent analysis identified a decrease in the HER-2 tissue control that had escaped notice by subjective evaluation. The decrement was due to heterogeneity in the tissue control itself. At institution 2, we identified a 1-day sudden drop in the PR tissue control, also undetected by subjective evaluation, due to counterstain variability. At institution 3, a QC shift was identified, but only with 1 of 2 controls mounted on each slide. The QC shift was due to use of the instrument's selective reagent drop zones dispense feature. None of these events affected patient diagnoses. These case examples illustrate that subjective QC evaluation of tissue controls can detect gross assayAbstract : Almost all clinical laboratory tests use objective, quantitative measures of quality control (QC), incorporating Levey-Jennings analysis and Westgard rules. Clinical immunohistochemistry (IHC) testing, in contrast, relies on subjective, qualitative QC review. The consequences of using Levey-Jennings analysis for QC assessment in clinical IHC testing are not known. To investigate this question, we conducted a 1- to 2-month pilot test wherein the QC for either human epidermal growth factor receptor 2 (HER-2) or progesterone receptor (PR) in 3 clinical IHC laboratories was quantified and analyzed with Levey-Jennings graphs. Moreover, conventional tissue controls were supplemented with a new QC comprised of HER-2 or PR peptide antigens coupled onto 8 μm glass beads. At institution 1, this more stringent analysis identified a decrease in the HER-2 tissue control that had escaped notice by subjective evaluation. The decrement was due to heterogeneity in the tissue control itself. At institution 2, we identified a 1-day sudden drop in the PR tissue control, also undetected by subjective evaluation, due to counterstain variability. At institution 3, a QC shift was identified, but only with 1 of 2 controls mounted on each slide. The QC shift was due to use of the instrument's selective reagent drop zones dispense feature. None of these events affected patient diagnoses. These case examples illustrate that subjective QC evaluation of tissue controls can detect gross assay failure but not subtle changes. The fact that QC issues arose from each site, and in only a pilot study, suggests that immunohistochemical stain variability may be an underappreciated problem. … (more)
- Is Part Of:
- Applied immunohistochemistry & molecular morphology. Volume 24:Issue 10(2016)
- Journal:
- Applied immunohistochemistry & molecular morphology
- Issue:
- Volume 24:Issue 10(2016)
- Issue Display:
- Volume 24, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 24
- Issue:
- 10
- Issue Sort Value:
- 2016-0024-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-11
- Subjects:
- quality control -- immunohistochemistry -- Levey-Jennings -- image analysis -- quantitative
Diagnostic immunohistochemistry -- Periodicals
Immunohistochemistry -- Periodicals
Cells -- Morphology -- Periodicals
Molecular diagnosis -- Periodicals
616.079 - Journal URLs:
- http://journals.lww.com/appliedimmunohist/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PAI.0000000000000260 ↗
- Languages:
- English
- ISSNs:
- 1541-2016
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1573.140000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 35.xml