Atmospheric pressure chemical ionization of explosives induced by soft X‐radiation in ion mobility spectrometry: mass spectrometric investigation of the ionization reactions of drift gasses, dopants and alkyl nitrates. (29th June 2016)
- Record Type:
- Journal Article
- Title:
- Atmospheric pressure chemical ionization of explosives induced by soft X‐radiation in ion mobility spectrometry: mass spectrometric investigation of the ionization reactions of drift gasses, dopants and alkyl nitrates. (29th June 2016)
- Main Title:
- Atmospheric pressure chemical ionization of explosives induced by soft X‐radiation in ion mobility spectrometry: mass spectrometric investigation of the ionization reactions of drift gasses, dopants and alkyl nitrates
- Authors:
- Riebe, Daniel
Erler, Alexander
Ritschel, Thomas
Beitz, Toralf
Löhmannsröben, Hans‐Gerd
Beil, Andreas
Blaschke, Michael
Ludwig, Thomas - Abstract:
- Abstract : A promising replacement for the radioactive sources commonly encountered in ion mobility spectrometers is a miniaturized, energy‐efficient photoionization source that produce the reactant ions via soft X‐radiation (2.8 keV). In order to successfully apply the photoionization source, it is imperative to know the spectrum of reactant ions and the subsequent ionization reactions leading to the detection of analytes. To that end, an ionization chamber based on the photoionization source that reproduces the ionization processes in the ion mobility spectrometer and facilitates efficient transfer of the product ions into a mass spectrometer was developed. Photoionization of pure gasses and gas mixtures containing air, N2, CO2 and N2 O and the dopant CH2 Cl2 is discussed. The main product ions of photoionization are identified and compared with the spectrum of reactant ions formed by radioactive and corona discharge sources on the basis of literature data. The results suggest that photoionization by soft X‐radiation in the negative mode is more selective than the other sources. In air, adduct ions of O2 – with H2 O and CO2 were exclusively detected. Traces of CO2 impact the formation of adduct ions of O2 – and Cl – (upon addition of dopant) and are capable of suppressing them almost completely at high CO2 concentrations. Additionally, the ionization products of four alkyl nitrates (ethylene glycol dinitrate, nitroglycerin, erythritol tetranitrate and pentaerythritolAbstract : A promising replacement for the radioactive sources commonly encountered in ion mobility spectrometers is a miniaturized, energy‐efficient photoionization source that produce the reactant ions via soft X‐radiation (2.8 keV). In order to successfully apply the photoionization source, it is imperative to know the spectrum of reactant ions and the subsequent ionization reactions leading to the detection of analytes. To that end, an ionization chamber based on the photoionization source that reproduces the ionization processes in the ion mobility spectrometer and facilitates efficient transfer of the product ions into a mass spectrometer was developed. Photoionization of pure gasses and gas mixtures containing air, N2, CO2 and N2 O and the dopant CH2 Cl2 is discussed. The main product ions of photoionization are identified and compared with the spectrum of reactant ions formed by radioactive and corona discharge sources on the basis of literature data. The results suggest that photoionization by soft X‐radiation in the negative mode is more selective than the other sources. In air, adduct ions of O2 – with H2 O and CO2 were exclusively detected. Traces of CO2 impact the formation of adduct ions of O2 – and Cl – (upon addition of dopant) and are capable of suppressing them almost completely at high CO2 concentrations. Additionally, the ionization products of four alkyl nitrates (ethylene glycol dinitrate, nitroglycerin, erythritol tetranitrate and pentaerythritol tetranitrate) formed by atmospheric pressure chemical ionization induced by X‐ray photoionization in different gasses (air, N2 and N2 O) and dopants (CH2 Cl2, C2 H5 Br and CH3 I) are investigated. The experimental studies are complemented by density functional theory calculations of the most important adduct ions of the alkyl nitrates (M) used for their spectrometric identification. In addition to the adduct ions [M + NO3 ] – and [M + Cl] –, adduct ions such as [M + N2 O2 ] –, [M + Br] – and [M + I] – were detected, and their gas‐phase structures and energetics are investigated by density functional theory calculations. Copyright © 2016 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Journal of mass spectrometry. Volume 51:Number 8(2016)
- Journal:
- Journal of mass spectrometry
- Issue:
- Volume 51:Number 8(2016)
- Issue Display:
- Volume 51, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 51
- Issue:
- 8
- Issue Sort Value:
- 2016-0051-0008-0000
- Page Start:
- 566
- Page End:
- 577
- Publication Date:
- 2016-06-29
- Subjects:
- ion mobility spectrometry -- mass spectrometry -- explosives -- X‐ray -- photoionization -- alkyl nitrates
Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jms.3784 ↗
- Languages:
- English
- ISSNs:
- 1076-5174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.179500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1330.xml