Integrity of Damage Control Posterior Spinal Fusion Constructs for Patients With Polytrauma: A Biomechanical Investigation. Issue 23 (December 2015)
- Record Type:
- Journal Article
- Title:
- Integrity of Damage Control Posterior Spinal Fusion Constructs for Patients With Polytrauma: A Biomechanical Investigation. Issue 23 (December 2015)
- Main Title:
- Integrity of Damage Control Posterior Spinal Fusion Constructs for Patients With Polytrauma
- Authors:
- Pekmezci, Murat
Herfat, Safa
Theologis, Alexander A.
Viscogliosi, Paul
Demirkiran, Gokhan
McClellan, R. Trigg
Ames, Christopher - Abstract:
- Abstract : Study Design: Biomechanical. Objective: Evaluate spinal stability achieved with different levels of posterior percutaneous fixation (postPerc) for thoracolumbar fractures in cadavers subjected to ICU activities. Summary of Background Data: "Spine damage control" involves postPerc performed within 24 hours of injury and staged, elective, definitive stabilization. Amount of instrumentation needed to initially achieve adequate spinal stability, minimize morbidity, and accommodate ICU care needs between stages are not defined. Methods: In full-unembalmed cadavers motion-tracking sensors were placed at T11 and L1. A T12 corpectomy with PLC injury was stabilized with 1, 2, and 3 levels of PostPerc above/below the injury. Motions between T11 and L1 were measured during Log-Roll and Sit-Up on an ICU bed. After in situ testing, anatomic spinal motion ranges were determined under pure moment loads. Results: 5 cadavers were evaluated. For Log-Roll, 2 and 3 levels above/below restored stability to intact, whereas 1 level above/below did not for axial rotation. For translation, all instrumentation restored stability to intact. During Sit-Up, a linear increase in flexion was observed. At 45° Sit-Up, 2 and 3 levels above/below were similar to intact for flexion; 1 level above/below had significantly more flexion. All instrumentations restored translation to intact for Sit-Up; significantly more axial collapse occurred for instrumentation compared with intact. During ex situAbstract : Study Design: Biomechanical. Objective: Evaluate spinal stability achieved with different levels of posterior percutaneous fixation (postPerc) for thoracolumbar fractures in cadavers subjected to ICU activities. Summary of Background Data: "Spine damage control" involves postPerc performed within 24 hours of injury and staged, elective, definitive stabilization. Amount of instrumentation needed to initially achieve adequate spinal stability, minimize morbidity, and accommodate ICU care needs between stages are not defined. Methods: In full-unembalmed cadavers motion-tracking sensors were placed at T11 and L1. A T12 corpectomy with PLC injury was stabilized with 1, 2, and 3 levels of PostPerc above/below the injury. Motions between T11 and L1 were measured during Log-Roll and Sit-Up on an ICU bed. After in situ testing, anatomic spinal motion ranges were determined under pure moment loads. Results: 5 cadavers were evaluated. For Log-Roll, 2 and 3 levels above/below restored stability to intact, whereas 1 level above/below did not for axial rotation. For translation, all instrumentation restored stability to intact. During Sit-Up, a linear increase in flexion was observed. At 45° Sit-Up, 2 and 3 levels above/below were similar to intact for flexion; 1 level above/below had significantly more flexion. All instrumentations restored translation to intact for Sit-Up; significantly more axial collapse occurred for instrumentation compared with intact. During ex situ testing, 2 and 3 levels above/below were similar; 1 level above/below had significantly greater laxity in flexion, extension, and axial rotation. Conclusion: Posterior instrumentation 2 or 3 levels above/below a severe thoracolumbar fracture model can restore spinal stability back to its intact condition. 2 levels of fixation above/below this "worst-case scenario" is minimum fixation sufficient to provide absolute spinal stability in the ICU setting as a "Damage Control" technique in patients with polytrauma. In less severe injury models, 1 level of fixation above/below may provide adequate spinal stability; although this should be confirmed in future investigations. Level of Evidence: N/A … (more)
- Is Part Of:
- Spine. Volume 40:Issue 23(2015)
- Journal:
- Spine
- Issue:
- Volume 40:Issue 23(2015)
- Issue Display:
- Volume 40, Issue 23 (2015)
- Year:
- 2015
- Volume:
- 40
- Issue:
- 23
- Issue Sort Value:
- 2015-0040-0023-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12
- Subjects:
- biomechanical. -- burst fracture -- corpectomy -- percutaneous pedicle screws -- thoracolumbar -- trauma
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000001058 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 252.xml