Accuracy of Measurements With the iCare HOME Rebound Tonometer. Issue 6 (June 2016)
- Record Type:
- Journal Article
- Title:
- Accuracy of Measurements With the iCare HOME Rebound Tonometer. Issue 6 (June 2016)
- Main Title:
- Accuracy of Measurements With the iCare HOME Rebound Tonometer
- Authors:
- Termühlen, Julia
Mihailovic, Natasa
Alnawaiseh, Maged
Dietlein, Thomas S.
Rosentreter, André - Abstract:
- Abstract : Purpose: To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with the newly available iCare HOME (RTHOME) rebound tonometer compared with the iCare ONE (RTONE) tonometer and Goldmann applanation tonometry (GAT), and possible correlation with central corneal thickness (CCT). Materials and Methods: IOP measurements were obtained from 154 patients by an ophthalmologist (doc) using each of the above-mentioned tonometers. In addition, patients (pat) measured their own IOP with the RTHOME and RTONE. The means and SD of results obtained with the different tonometers were compared. Agreement between the tonometers was calculated using the Bland-Altman method. Results: Mean IOPs for the right eyes only were 15.9±6.4 mm Hg (RTONEdoc), 15.8±6.4 mm Hg (RTONEpat), 15.0±5.9 mm Hg (RTHOMEdoc), 14.9±6.3 mm Hg (RTHOMEpat), and 15.8±4.4 mm Hg (GAT). Bland-Altman analysis revealed mean differences (bias) between RTONEdoc and RTHOMEdoc, between RTHOMEdoc and RTHOMEpat, and between RTHOMEdoc and GAT of 0.8, 0.1, and −0.8 mm Hg, respectively, with 95% limits of agreement of −3.5 to 5.2, −4.9 to 5.1, and −7.2 to 5.6 mm Hg, respectively. Linear regression of the comparisons revealed a proportional error over the range of pressures examined in the case of RTHOMEdoc versus GAT (slope=0.32, P <0.001). Considering the data from all eyes, the difference between RTHOMEdoc and GAT correlated significantly with the CCT ( P =0.01). Conclusion: RTHOME readings correlateAbstract : Purpose: To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with the newly available iCare HOME (RTHOME) rebound tonometer compared with the iCare ONE (RTONE) tonometer and Goldmann applanation tonometry (GAT), and possible correlation with central corneal thickness (CCT). Materials and Methods: IOP measurements were obtained from 154 patients by an ophthalmologist (doc) using each of the above-mentioned tonometers. In addition, patients (pat) measured their own IOP with the RTHOME and RTONE. The means and SD of results obtained with the different tonometers were compared. Agreement between the tonometers was calculated using the Bland-Altman method. Results: Mean IOPs for the right eyes only were 15.9±6.4 mm Hg (RTONEdoc), 15.8±6.4 mm Hg (RTONEpat), 15.0±5.9 mm Hg (RTHOMEdoc), 14.9±6.3 mm Hg (RTHOMEpat), and 15.8±4.4 mm Hg (GAT). Bland-Altman analysis revealed mean differences (bias) between RTONEdoc and RTHOMEdoc, between RTHOMEdoc and RTHOMEpat, and between RTHOMEdoc and GAT of 0.8, 0.1, and −0.8 mm Hg, respectively, with 95% limits of agreement of −3.5 to 5.2, −4.9 to 5.1, and −7.2 to 5.6 mm Hg, respectively. Linear regression of the comparisons revealed a proportional error over the range of pressures examined in the case of RTHOMEdoc versus GAT (slope=0.32, P <0.001). Considering the data from all eyes, the difference between RTHOMEdoc and GAT correlated significantly with the CCT ( P =0.01). Conclusion: RTHOME readings correlate well with the GAT results although some limitations such as dependency of readings on CCT and increasing differences at lower and higher IOP levels need to be taken into account. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 25:Issue 6(2016:Aug.)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 25:Issue 6(2016:Aug.)
- Issue Display:
- Volume 25, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 25
- Issue:
- 6
- Issue Sort Value:
- 2016-0025-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-06
- Subjects:
- rebound tonometry -- applanation tonometry -- glaucoma -- IOP home monitoring -- iCare HOME
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000000390 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1389.xml