Automated control of endotracheal tube cuff pressure during simulated flight. (November 2016)
- Record Type:
- Journal Article
- Title:
- Automated control of endotracheal tube cuff pressure during simulated flight. (November 2016)
- Main Title:
- Automated control of endotracheal tube cuff pressure during simulated flight
- Authors:
- Blakeman, Thomas
Rodriquez, Dario
Woods, James
Cox, Daniel
Elterman, Joel
Branson, Richard - Abstract:
- Abstract : BACKGROUND: Successful mechanical ventilation requires that the airway be controlled by an endotracheal tube (ETT) with an inflatable cuff to seal the airway. Aeromedical evacuation represents a unique challenge in which to manage ETT cuffs. We evaluated three methods of automatic ETT cuff pressure adjustment during changes in altitude in an altitude chamber. METHODS: Size 7.5 and 8.0 mm ETTs that are currently included in the Critical Care Air Transport Team allowance standard were used for the evaluation. Three automatic cuff pressure controllers—Intellicuff, Hamilton Medical; Pyton, ARM Medical; and Cuff Sentry, Outcome Solutions—were used to manage cuff pressures. The fourth group had cuff pressure set at sea level without further adjustment. Each ETT was inserted into a tracheal model and taken to 8, 000 feet and then to 16, 000 feet at 2, 500 ft/min. Baseline cuff pressure at sea level was approximately 25 cm H2 O. RESULTS: Mean cuff pressure at both altitudes with both size ETTs was as follows: Control arm, 141 ± 64 cm H2 O; Pyton, 25 ± 0.8 cm H2 O; Cuff Sentry, 22 ± 0.3 cm H2 O; and Intellicuff, 29 ± 6.6 cm H2 O. The mean time that cuff pressure was >30 cm H2 O using Intellicuff at both altitudes was 2.8 ± 0.8 minutes. Pressure differences from baseline in the control arm and with Intellicuff were statistically significant. Cuff pressure with the Cuff Sentry tended to be lower than indicated on the device. CONCLUSIONS: Mean cuff pressures were within theAbstract : BACKGROUND: Successful mechanical ventilation requires that the airway be controlled by an endotracheal tube (ETT) with an inflatable cuff to seal the airway. Aeromedical evacuation represents a unique challenge in which to manage ETT cuffs. We evaluated three methods of automatic ETT cuff pressure adjustment during changes in altitude in an altitude chamber. METHODS: Size 7.5 and 8.0 mm ETTs that are currently included in the Critical Care Air Transport Team allowance standard were used for the evaluation. Three automatic cuff pressure controllers—Intellicuff, Hamilton Medical; Pyton, ARM Medical; and Cuff Sentry, Outcome Solutions—were used to manage cuff pressures. The fourth group had cuff pressure set at sea level without further adjustment. Each ETT was inserted into a tracheal model and taken to 8, 000 feet and then to 16, 000 feet at 2, 500 ft/min. Baseline cuff pressure at sea level was approximately 25 cm H2 O. RESULTS: Mean cuff pressure at both altitudes with both size ETTs was as follows: Control arm, 141 ± 64 cm H2 O; Pyton, 25 ± 0.8 cm H2 O; Cuff Sentry, 22 ± 0.3 cm H2 O; and Intellicuff, 29 ± 6.6 cm H2 O. The mean time that cuff pressure was >30 cm H2 O using Intellicuff at both altitudes was 2.8 ± 0.8 minutes. Pressure differences from baseline in the control arm and with Intellicuff were statistically significant. Cuff pressure with the Cuff Sentry tended to be lower than indicated on the device. CONCLUSIONS: Mean cuff pressures were within the recommended range with all three devices. Intellicuff had difficulty regulating the cuff pressure initially with increases in altitude but was able to reduce the pressure to a safe level during the stabilization period at each altitude. The Pyton and Cuff Sentry allowed the least variation in pressure throughout the evaluation, although the Cuff Sentry set pressure was less than the actual pressure. LEVEL OF EVIDENCE: Therapeutic study, level V. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Journal of trauma and acute care surgery. Volume 81(2016)Supplement 2
- Journal:
- Journal of trauma and acute care surgery
- Issue:
- Volume 81(2016)Supplement 2
- Issue Display:
- Volume 81, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 81
- Issue:
- 2
- Issue Sort Value:
- 2016-0081-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-11
- Subjects:
- Endotracheal tube -- cuff pressure -- altitude
Surgical intensive care -- Periodicals
Surgical emergencies -- Periodicals
Wounds and injuries -- Surgery -- Periodicals
617.026 - Journal URLs:
- http://journals.lww.com/jtrauma/pages/default.aspx ↗
http://ovidsp.tx.ovid.com/sp-3.5.0b/ovidweb.cgi?&S=NEIKFPIGHGDDBOHLNCALMDIBGLDKAA00&Browse=Toc+Children%7cNO%7cS.sh.2697_1327404888_15.2697_1327404888_27.2697_1327404888_28%7c273%7c50 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/TA.0000000000001234 ↗
- Languages:
- English
- ISSNs:
- 2163-0755
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5070.510500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1679.xml