A Pilot Evaluation Assessing the Ease of Use and Accuracy of the New Self/Home-Tonometer IcareHOME in Healthy Young Subjects. Issue 10 (October 2016)
- Record Type:
- Journal Article
- Title:
- A Pilot Evaluation Assessing the Ease of Use and Accuracy of the New Self/Home-Tonometer IcareHOME in Healthy Young Subjects. Issue 10 (October 2016)
- Main Title:
- A Pilot Evaluation Assessing the Ease of Use and Accuracy of the New Self/Home-Tonometer IcareHOME in Healthy Young Subjects
- Authors:
- Noguchi, Asuka
Nakakura, Shunsuke
Fujio, Yuki
Fukuma, Yasuko
Mori, Etsuko
Tabuchi, Hitoshi
Kiuchi, Yoshiaki - Abstract:
- Abstract : Purpose: We investigated the ease of use and accuracy of a new self/home-tonometer (IcareHOME) versus Goldmann applanation tonometry (GAT) and the Icare tonometer (Icare) by measuring the diurnal intraocular pressure (IOP). Patients and Methods: The right eyes of 43 healthy young subjects were studied. The IOP was measured using the IcareHOME, GAT, and Icare 6 times a day, every 2 hours, from 8:00 to 18:00. The coincidence of the diurnal curves among all tonometers was analyzed using a linear mixed model. The intradevice and interdevice agreement was evaluated using the intraclass correlation coefficients (ICC) and Bland-Altman method. The subjects' perception of the IcareHOME was evaluated using a questionnaire. Results: The liner mixed model showed similar diurnal IOP curves for all tonometers ( P =0.543); however, significant differences were observed between the tonometers over time ( P <0.001). The intradevice repeatability was ICC>0.8 among all tonometers, although the interdevice agreement was lowest between the IcareHOME and GAT (ICC=0.641). The IOP values were significantly lower for the IcareHOME than for the GAT at 12:00, 16:00, and 18:00 ( P <0.05, Tukey-Kramer test). The mean differences between the Icare and IcareHOME and GAT and IcareHOME were 0.83 and 1.03 mm Hg, respectively (95% limit of agreement: −4.17 to 5.84 mm Hg and −3.91 to 5.98 mm Hg, respectively). Regarding the subjects' perception of handling the IcareHOME, 17 (39.5%) subjects answeredAbstract : Purpose: We investigated the ease of use and accuracy of a new self/home-tonometer (IcareHOME) versus Goldmann applanation tonometry (GAT) and the Icare tonometer (Icare) by measuring the diurnal intraocular pressure (IOP). Patients and Methods: The right eyes of 43 healthy young subjects were studied. The IOP was measured using the IcareHOME, GAT, and Icare 6 times a day, every 2 hours, from 8:00 to 18:00. The coincidence of the diurnal curves among all tonometers was analyzed using a linear mixed model. The intradevice and interdevice agreement was evaluated using the intraclass correlation coefficients (ICC) and Bland-Altman method. The subjects' perception of the IcareHOME was evaluated using a questionnaire. Results: The liner mixed model showed similar diurnal IOP curves for all tonometers ( P =0.543); however, significant differences were observed between the tonometers over time ( P <0.001). The intradevice repeatability was ICC>0.8 among all tonometers, although the interdevice agreement was lowest between the IcareHOME and GAT (ICC=0.641). The IOP values were significantly lower for the IcareHOME than for the GAT at 12:00, 16:00, and 18:00 ( P <0.05, Tukey-Kramer test). The mean differences between the Icare and IcareHOME and GAT and IcareHOME were 0.83 and 1.03 mm Hg, respectively (95% limit of agreement: −4.17 to 5.84 mm Hg and −3.91 to 5.98 mm Hg, respectively). Regarding the subjects' perception of handling the IcareHOME, 17 (39.5%) subjects answered "easy to use, " 20 (46.5%) answered "normal, " and six (13.9%) answered "difficult to use." Conclusions: The IcareHOME can be used as a self/home-tonometer; however, it may result in lower IOP values. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 25:Issue 10(2016)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 25:Issue 10(2016)
- Issue Display:
- Volume 25, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 25
- Issue:
- 10
- Issue Sort Value:
- 2016-0025-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-10
- Subjects:
- rebound tonometer -- glaucoma -- IcareHOME -- Icare -- diurnal intraocular pressure
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000000457 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2686.xml