Reverse Mismatch Pattern in Cardiac 18F-FDG Viability PET/CT Is Not Associated With Poor Outcome of Revascularization: A Retrospective Outcome Study of 91 Patients With Heart Failure. (October 2016)
- Record Type:
- Journal Article
- Title:
- Reverse Mismatch Pattern in Cardiac 18F-FDG Viability PET/CT Is Not Associated With Poor Outcome of Revascularization: A Retrospective Outcome Study of 91 Patients With Heart Failure. (October 2016)
- Main Title:
- Reverse Mismatch Pattern in Cardiac 18F-FDG Viability PET/CT Is Not Associated With Poor Outcome of Revascularization
- Authors:
- Hansen, Allan Kjeldsen
Gejl, Michael
Bouchelouche, Kirsten
Tolbod, Lars Poulsen
Gormsen, Lars Christian - Abstract:
- Abstract : Purpose: Revascularization strategies in patients with ischemic heart failure (HF) should be based on evidence of reversible perfusion defects and myocardial viability. Myocardial viability assessment is preferably based on dual isotope PET using perfusion and metabolism tracers. However, in a nonnegligible subset of HF patients, reverse mismatch (RM) pattern (reduced glucose uptake relative to perfusion) of unknown origin is observed. We aimed to investigate determinants of RM and the impact of RM on the subsequent improvement in left ventricular function by revascularization. Patients and Methods: Ninety-one patients (12 women, 25 with diabetes) with HF undergoing 82 Rb perfusion PET and hyperinsulinemic-euglycemic clamp 18 F-FDG viability PET were retrospectively reviewed. Results: Follow-up time was 12 to 33 months. In 30 of 91 patients, hypometabolic myocardium exceeded the percentage of hypoperfused myocardium; however, only in 12 of 91 patients was the RM considered significant (percentage RM in the left ventricle, 42.5 ± 12.9 [reverse patients] vs 14.1 ± 8.6 [scar and hibernation patients]; P < 0.001). Diabetes status per se did not predict RM, but a significant inverse correlation between insulin sensitivity and RM was observed. The frequency of hospitalization, cardiac death, and myocardial infarctions were not significantly higher in RM patients. Reverse mismatch patients benefited from revascularization to the same extent as patient with normalAbstract : Purpose: Revascularization strategies in patients with ischemic heart failure (HF) should be based on evidence of reversible perfusion defects and myocardial viability. Myocardial viability assessment is preferably based on dual isotope PET using perfusion and metabolism tracers. However, in a nonnegligible subset of HF patients, reverse mismatch (RM) pattern (reduced glucose uptake relative to perfusion) of unknown origin is observed. We aimed to investigate determinants of RM and the impact of RM on the subsequent improvement in left ventricular function by revascularization. Patients and Methods: Ninety-one patients (12 women, 25 with diabetes) with HF undergoing 82 Rb perfusion PET and hyperinsulinemic-euglycemic clamp 18 F-FDG viability PET were retrospectively reviewed. Results: Follow-up time was 12 to 33 months. In 30 of 91 patients, hypometabolic myocardium exceeded the percentage of hypoperfused myocardium; however, only in 12 of 91 patients was the RM considered significant (percentage RM in the left ventricle, 42.5 ± 12.9 [reverse patients] vs 14.1 ± 8.6 [scar and hibernation patients]; P < 0.001). Diabetes status per se did not predict RM, but a significant inverse correlation between insulin sensitivity and RM was observed. The frequency of hospitalization, cardiac death, and myocardial infarctions were not significantly higher in RM patients. Reverse mismatch patients benefited from revascularization to the same extent as patient with normal metabolic patterns. Conclusions: Reverse mismatch is common among HF patients (~15%) and is inversely correlated to insulin sensitivity. It is not, however, associated with increased cardiac morbidity and mortality and does not predict a worse outcome after revascularization. … (more)
- Is Part Of:
- Clinical nuclear medicine. Volume 41:Number 10(2016)
- Journal:
- Clinical nuclear medicine
- Issue:
- Volume 41:Number 10(2016)
- Issue Display:
- Volume 41, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 10
- Issue Sort Value:
- 2016-0041-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-10
- Subjects:
- heart failure -- 18F-FDG -- 82Rb -- dual isotope PET -- myocardial viability -- reverse mismatch pattern
Nuclear medicine -- Periodicals
Radioisotope scanning -- Periodicals
Nuclear Medicine -- Periodicals
616.07575 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00003072-000000000-00000 ↗
http://journals.lww.com/nuclearmed/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLU.0000000000001312 ↗
- Languages:
- English
- ISSNs:
- 0363-9762
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.314000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 350.xml