Diffusion Tensor Imaging of Lumbar Nerve Roots: Comparison Between Fast Readout-Segmented and Selective-Excitation Acquisitions. Issue 8 (August 2016)
- Record Type:
- Journal Article
- Title:
- Diffusion Tensor Imaging of Lumbar Nerve Roots: Comparison Between Fast Readout-Segmented and Selective-Excitation Acquisitions. Issue 8 (August 2016)
- Main Title:
- Diffusion Tensor Imaging of Lumbar Nerve Roots
- Authors:
- Manoliu, Andrei
Ho, Michael
Nanz, Daniel
Piccirelli, Marco
Dappa, Evelyn
Klarhöfer, Markus
Del Grande, Filippo
Kuhn, Felix Pierre - Abstract:
- Abstract : Objectives: The aim of this study was to compare the quality of recently emerged advanced diffusion tensor imaging (DTI) techniques with conventional single-shot echo-planar imaging (EPI) in a functional assessment of lumbar nerve roots. Materials and Methods: The institutional review board approved the study including 12 healthy volunteers. Diffusion tensor imaging was performed at 3 T (MAGNETOM Skyra; Siemens Healthcare) with b -values of 0 and 700 s/mm 2 and an isotropic spatial resolution for subsequent multiplanar reformatting. The nerve roots L2 to S1 were imaged in coronal orientation with readout-segmented EPI (rs-DTI) and selective-excitation EPI (sTX-DTI) with an acquisition time of 5 minutes each, and in axial orientation with single-shot EPI (ss-DTI) with an acquisition time of 12 minutes (scan parameters as in recent literature). Two independent readers qualitatively and quantitatively assessed image quality. Results: The interobserver reliability ranged from "substantial" to "almost perfect" for all examined parameter and all 3 sequences (κ = 0.70–0.94). Overall image quality was rated higher, and artifact levels were scored lower for rs-DTI and sTX-DTI than for ss-DTI ( P = 0.007–0.027), while fractional anisotropy and signal-to-noise ratio values were similar for all sequences ( P ≥ 0.306 and P ≥ 0.100, respectively). Contrast-to-noise ratios were significantly higher for rs-DTI and ss-DTI than for sTX-DTI ( P = 0.004–0.013). Conclusions: DespiteAbstract : Objectives: The aim of this study was to compare the quality of recently emerged advanced diffusion tensor imaging (DTI) techniques with conventional single-shot echo-planar imaging (EPI) in a functional assessment of lumbar nerve roots. Materials and Methods: The institutional review board approved the study including 12 healthy volunteers. Diffusion tensor imaging was performed at 3 T (MAGNETOM Skyra; Siemens Healthcare) with b -values of 0 and 700 s/mm 2 and an isotropic spatial resolution for subsequent multiplanar reformatting. The nerve roots L2 to S1 were imaged in coronal orientation with readout-segmented EPI (rs-DTI) and selective-excitation EPI (sTX-DTI) with an acquisition time of 5 minutes each, and in axial orientation with single-shot EPI (ss-DTI) with an acquisition time of 12 minutes (scan parameters as in recent literature). Two independent readers qualitatively and quantitatively assessed image quality. Results: The interobserver reliability ranged from "substantial" to "almost perfect" for all examined parameter and all 3 sequences (κ = 0.70–0.94). Overall image quality was rated higher, and artifact levels were scored lower for rs-DTI and sTX-DTI than for ss-DTI ( P = 0.007–0.027), while fractional anisotropy and signal-to-noise ratio values were similar for all sequences ( P ≥ 0.306 and P ≥ 0.100, respectively). Contrast-to-noise ratios were significantly higher for rs-DTI and ss-DTI than for sTX-DTI ( P = 0.004–0.013). Conclusions: Despite shorter acquisition times, rs-DTI and sTX-DTI produced images of higher quality with smaller geometrical distortions than the current standard of reference, ss-DTI. Thus, DTI acquisitions in the coronal plane, requiring fewer slices for full coverage of exiting nerve roots, may allow for functional neurography in scan times suitable for routine clinical practice. … (more)
- Is Part Of:
- Investigative radiology. Volume 51:Issue 8(2016:Aug.)
- Journal:
- Investigative radiology
- Issue:
- Volume 51:Issue 8(2016:Aug.)
- Issue Display:
- Volume 51, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 51
- Issue:
- 8
- Issue Sort Value:
- 2016-0051-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-08
- Subjects:
- MR neurography -- DTI techniques -- DTI peripheral nerves -- lumbar spine -- lumbar nerve roots
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000260 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: