Brito, Carlos - Abstract:
- Abstract : Purpose: To evaluate the ability of Swept-source optical coherence tomography (SS-OCT) in detecting early endothelial graft detachment after Descemet membrane endothelial keratoplasty (DMEK) and to determine the possible causes of graft detachment using 2 different protocols for anterior segment (AS) imaging. Methods: Eight eyes from 8 consecutive DMEK surgeries were evaluated. High-resolution images were captured with SS-OCT using 2 different radial protocols for AS imaging (16- and 6-mm radial protocols). Central and peripheral corneal changes were evaluated. Results: All eyes developed early graft detachment detectable with the SS-OCT. The 16-mm radial protocol scanned the cornea detecting early graft detachment in 6 out of 8 cases. The 6-mm radial protocol provided detailed images of the cornea, detecting early detachment in all cases. Stromal irregularities and small remnants only detectable using SS-OCT were the possible cause of detachment in 3 cases. One of the 8 eyes had air reinjection. The detachment in that eye was apparent by slit-lamp examination. The detachments spontaneously resolved in the other 7 eyes. AS SS-OCT evaluation was found to have added diagnostic value to biomicroscopy in 5 of these eyes (64.5%). Conclusions: AS SS-OCT is sensitive in detecting early graft detachment after DMEK. The 16-mm radial protocol of Triton SS-OCT is superior regarding quick scan of the entire cornea providing a general visualization of the DMEK graft. The 6-mmAbstract : Purpose: To evaluate the ability of Swept-source optical coherence tomography (SS-OCT) in detecting early endothelial graft detachment after Descemet membrane endothelial keratoplasty (DMEK) and to determine the possible causes of graft detachment using 2 different protocols for anterior segment (AS) imaging. Methods: Eight eyes from 8 consecutive DMEK surgeries were evaluated. High-resolution images were captured with SS-OCT using 2 different radial protocols for AS imaging (16- and 6-mm radial protocols). Central and peripheral corneal changes were evaluated. Results: All eyes developed early graft detachment detectable with the SS-OCT. The 16-mm radial protocol scanned the cornea detecting early graft detachment in 6 out of 8 cases. The 6-mm radial protocol provided detailed images of the cornea, detecting early detachment in all cases. Stromal irregularities and small remnants only detectable using SS-OCT were the possible cause of detachment in 3 cases. One of the 8 eyes had air reinjection. The detachment in that eye was apparent by slit-lamp examination. The detachments spontaneously resolved in the other 7 eyes. AS SS-OCT evaluation was found to have added diagnostic value to biomicroscopy in 5 of these eyes (64.5%). Conclusions: AS SS-OCT is sensitive in detecting early graft detachment after DMEK. The 16-mm radial protocol of Triton SS-OCT is superior regarding quick scan of the entire cornea providing a general visualization of the DMEK graft. The 6-mm radial protocol provides detailed corneal imaging of a selected area, which is useful for evaluating structural alterations that are not detectable with larger scans and may affect the adherence of the endothelial graft. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Cornea. Volume 35:Issue 10(2016)
- Journal:
- Cornea
- Issue:
- Volume 35:Issue 10(2016)
- Issue Display:
- Volume 35, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 35
- Issue:
- 10
- Issue Sort Value:
- 2016-0035-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-10
- Subjects:
- Descemet membrane endothelial keratoplasty -- graft detachment -- swept-source optical coherence tomography
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000000925 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2750.xml