Plasma levels of chemokine ligand 20 and chemokine receptor 6 in patients with sepsis: A case control study. Issue 5 (May 2016)
- Record Type:
- Journal Article
- Title:
- Plasma levels of chemokine ligand 20 and chemokine receptor 6 in patients with sepsis: A case control study. Issue 5 (May 2016)
- Main Title:
- Plasma levels of chemokine ligand 20 and chemokine receptor 6 in patients with sepsis
- Authors:
- Klaus, Daniel A.
Seemann, Rudolf
Roth-Walter, Franziska
Einwallner, Elisa
Motal, Michael C.
Tudor, Bianca
Lebherz-Eichinger, Diana
Wiegele, Marion
Krenn, Claus G.
Roth, Georg A. - Abstract:
- Abstract : BACKGROUND: Chemokine ligand 20 (CCL20) is a chemokine released by mainly liver and blood leucocytes. Particularly under pro-inflammatory circumstances it triggers chemotaxis of lymphocytes and dendritic cells via activating receptor chemokine receptor 6 (CCR6) that is specific to it. In experimental sepsis models, the chemokine–receptor pair has been identified as a potential pathophysiological axis affecting mortality. OBJECTIVE: Measurement of CCL20 and CCR6 plasma levels in septic patients compared with postsurgical, nonseptic patients. DESIGN: Case control study. SETTING: Surgical ICUs of the Department of Anaesthesiology, General Hospital of Vienna, Vienna, Austria. PATIENTS: Plasma levels were measured in 46 patients with sepsis, severe sepsis or septic shock according to current American College of Chest Physicians/Society of Critical Care Medicine criteria at the day of sepsis onset. Plasma levels in 36 postsurgical controls without sepsis admitted to the ICU were investigated. Plasma concentrations were determined by using commercially available ELISA kits. Data are given as median and interquartile range (IQR). MAIN OUTCOME MEASURES: CCL20 and CCR6 plasma levels. RESULTS: CCL20 plasma levels were significantly increased in the sepsis group: 220.9 pg ml −1 (IQR, 72.8 to 540.1) compared with the ICU controls: 37.0 pg ml −1 (IQR 6.5 to 83.6) ( P < 0.0001). Significantly elevated CCR6 levels were found in the sepsis group: 2.47 ng ml −1 (IQR 0.92 to 5.54)Abstract : BACKGROUND: Chemokine ligand 20 (CCL20) is a chemokine released by mainly liver and blood leucocytes. Particularly under pro-inflammatory circumstances it triggers chemotaxis of lymphocytes and dendritic cells via activating receptor chemokine receptor 6 (CCR6) that is specific to it. In experimental sepsis models, the chemokine–receptor pair has been identified as a potential pathophysiological axis affecting mortality. OBJECTIVE: Measurement of CCL20 and CCR6 plasma levels in septic patients compared with postsurgical, nonseptic patients. DESIGN: Case control study. SETTING: Surgical ICUs of the Department of Anaesthesiology, General Hospital of Vienna, Vienna, Austria. PATIENTS: Plasma levels were measured in 46 patients with sepsis, severe sepsis or septic shock according to current American College of Chest Physicians/Society of Critical Care Medicine criteria at the day of sepsis onset. Plasma levels in 36 postsurgical controls without sepsis admitted to the ICU were investigated. Plasma concentrations were determined by using commercially available ELISA kits. Data are given as median and interquartile range (IQR). MAIN OUTCOME MEASURES: CCL20 and CCR6 plasma levels. RESULTS: CCL20 plasma levels were significantly increased in the sepsis group: 220.9 pg ml −1 (IQR, 72.8 to 540.1) compared with the ICU controls: 37.0 pg ml −1 (IQR 6.5 to 83.6) ( P < 0.0001). Significantly elevated CCR6 levels were found in the sepsis group: 2.47 ng ml −1 (IQR 0.92 to 5.54) compared with the controls: 0.59 ng ml −1 (IQR 0.17 to 1.48) ( P < 0.0001). Both CCL20 and CCR6 correlated with the maximum sequential organ failure assessment score (CCL20: P < 0.0001, CCR6: P < 0.0001). Length of ICU admission depended significantly on the logarithm of CCR6 ( P = 0.008) and sequential organ failure assessment maximum ( P < 0.0001). CONCLUSION: There were early increased plasma concentrations of CCL20 and CCR6 in patients with sepsis. CCL20 and CCR6 correlate with severity of illness in ICU patients. Levels of CCR6 predicted the length of patients' admission. … (more)
- Is Part Of:
- European journal of anaesthesiology. Volume 33:Issue 5(2016:May)
- Journal:
- European journal of anaesthesiology
- Issue:
- Volume 33:Issue 5(2016:May)
- Issue Display:
- Volume 33, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 33
- Issue:
- 5
- Issue Sort Value:
- 2016-0033-0005-0000
- Page Start:
- 348
- Page End:
- 355
- Publication Date:
- 2016-05
- Subjects:
- Anesthesiology -- Periodicals
Anesthesiology -- Periodicals
Anesthésiologie -- Périodiques
Anesthesiology
Periodicals
Electronic journals
617.96 - Journal URLs:
- http://journals.lww.com/ejanaesthesiology/pages/default.aspx ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2346/issues ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=eja ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00003643-000000000-00000 ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0265-0215 ↗ - DOI:
- 10.1097/EJA.0000000000000388 ↗
- Languages:
- English
- ISSNs:
- 0265-0215
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.722200
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2438.xml