Central Corneal Thickness Reproducibility among Ten Different Instruments. Issue 11 (November 2016)
- Record Type:
- Journal Article
- Title:
- Central Corneal Thickness Reproducibility among Ten Different Instruments. Issue 11 (November 2016)
- Main Title:
- Central Corneal Thickness Reproducibility among Ten Different Instruments
- Authors:
- Pierro, Luisa
Iuliano, Lorenzo
Gagliardi, Marco
Ambrosi, Alessandro
Rama, Paolo
Bandello, Francesco - Abstract:
- ABSTRACT: Purpose: To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. Methods: In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Results: Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852–0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon—Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss—RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device.ABSTRACT: Purpose: To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. Methods: In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Results: Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852–0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon—Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss—RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Conclusions: Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Optometry and vision science. Volume 93:Issue 11(2016)
- Journal:
- Optometry and vision science
- Issue:
- Volume 93:Issue 11(2016)
- Issue Display:
- Volume 93, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 93
- Issue:
- 11
- Issue Sort Value:
- 2016-0093-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-11
- Subjects:
- pachymetry -- central corneal thickness -- reproducibility -- conversion
Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000000974 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 340.xml