National Trends in the Use of Cardiac Resynchronization Therapy With or Without Implantable Cardioverter-Defibrillator. Issue 3 (19th January 2016)
- Record Type:
- Journal Article
- Title:
- National Trends in the Use of Cardiac Resynchronization Therapy With or Without Implantable Cardioverter-Defibrillator. Issue 3 (19th January 2016)
- Main Title:
- National Trends in the Use of Cardiac Resynchronization Therapy With or Without Implantable Cardioverter-Defibrillator
- Authors:
- Lindvall, Charlotta
Chatterjee, Neal A.
Chang, Yuchiao
Chernack, Betty
Jackson, Vicki A.
Singh, Jagmeet P.
Metlay, Joshua P. - Abstract:
- Abstract : Background—: Candidates for cardiac resynchronization therapy (CRT) receive either a biventricular pacemaker or a biventricular pacemaker with an implantable cardioverter-defibrillator (CRT-D). Optimal device selection remains challenging because the benefit of implantable cardioverter-defibrillator therapy may not be uniform, particularly in patients at competing risk of nonsudden death. Methods and Results—: In this serial cross-sectional study using the National Inpatient Sample database, we identified 311 086 admissions associated with CRT implant between 2006 to 2012. CRT-D was the most common device type (86.1%), including in patients ≥75 years of age with ≥5 Elixhauser comorbidities (75.5%). Multivariate predictors of CRT-D implant included demographic, clinical, and geographic factors: prior ventricular arrhythmia (rate ratio [RR], 1.14; 95% CI, 1.13–1.14), ischemic heart disease (RR, 1.11; 95% CI, 1.10–1.11), male sex (RR, 1.10; 95% CI, 1.09–1.10), black race (RR, 1.06; 95% CI: 1.04–1.07), and Northeast geographic region (RR, 1.06; 95% CI, 1.04–1.09). There was significant interhospital variation in the use of CRT-D (10–90 percentile range, 72.9%–98.0% CRT-D). Conclusions—: The majority of patients in this contemporary US cohort underwent implantation of CRT-D. Predictors of CRT-D implant included demographic, clinical, and geographic factors. In patient subgroups predicted to have an attenuated benefit from implantable cardioverter-defibrillator therapyAbstract : Background—: Candidates for cardiac resynchronization therapy (CRT) receive either a biventricular pacemaker or a biventricular pacemaker with an implantable cardioverter-defibrillator (CRT-D). Optimal device selection remains challenging because the benefit of implantable cardioverter-defibrillator therapy may not be uniform, particularly in patients at competing risk of nonsudden death. Methods and Results—: In this serial cross-sectional study using the National Inpatient Sample database, we identified 311 086 admissions associated with CRT implant between 2006 to 2012. CRT-D was the most common device type (86.1%), including in patients ≥75 years of age with ≥5 Elixhauser comorbidities (75.5%). Multivariate predictors of CRT-D implant included demographic, clinical, and geographic factors: prior ventricular arrhythmia (rate ratio [RR], 1.14; 95% CI, 1.13–1.14), ischemic heart disease (RR, 1.11; 95% CI, 1.10–1.11), male sex (RR, 1.10; 95% CI, 1.09–1.10), black race (RR, 1.06; 95% CI: 1.04–1.07), and Northeast geographic region (RR, 1.06; 95% CI, 1.04–1.09). There was significant interhospital variation in the use of CRT-D (10–90 percentile range, 72.9%–98.0% CRT-D). Conclusions—: The majority of patients in this contemporary US cohort underwent implantation of CRT-D. Predictors of CRT-D implant included demographic, clinical, and geographic factors. In patient subgroups predicted to have an attenuated benefit from implantable cardioverter-defibrillator therapy (older adults with multiple comorbidities), CRT-D remained the dominant device type. An improved understanding of the determinants of device selection may aid in decision making and ultimately better align patient risk with device benefit at the time of CRT implantation. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 133:Issue 3(2016)
- Journal:
- Circulation
- Issue:
- Volume 133:Issue 3(2016)
- Issue Display:
- Volume 133, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 133
- Issue:
- 3
- Issue Sort Value:
- 2016-0133-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01-19
- Subjects:
- cardiac resynchronization therapy -- cardiac resynchronization therapy devices -- defibrillators, implantable -- electric countershock -- heart failure
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.115.018830 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2853.xml