A Method to Prevent Occipitocervical Joint Violation Using Plain Radiography During Percutaneous Anterior Transarticular Screw Fixation. Issue 17 (September 2016)
- Record Type:
- Journal Article
- Title:
- A Method to Prevent Occipitocervical Joint Violation Using Plain Radiography During Percutaneous Anterior Transarticular Screw Fixation. Issue 17 (September 2016)
- Main Title:
- A Method to Prevent Occipitocervical Joint Violation Using Plain Radiography During Percutaneous Anterior Transarticular Screw Fixation
- Authors:
- Jin, Hai-Ming
Xu, Dao-Liang
Xuan, Jun
Chen, Jiao-Xiang
Goswami, Amit
Chen, Xi-Bang
Wu, Ai-Min
Chi, Yong-Long
Wang, Xiang-Yang - Abstract:
- Abstract : Study Design: A prospective study of anterior transarticular screw (ATS) fixation patients. Objective: To develop a method to determine screw tip position through plain radiography after percutaneous ATS fixation to prevent occipitocervical joint (OCJ) violation. Summary of Background Data: No studies using plain radiography to prevent OCJ violation during percutaneous ATS fixation have been performed. Methods: In total, 34 subjects (with 68 screws) who had undergone percutaneous ATS fixation were enrolled. To evaluate the screw tip location in relation to the C1 lateral mass (LM), the screw tip positions were graded 1, 2, or 3 on anteroposterior (AP) radiographs, and I, II, or III on lateral radiographs. OCJ violation was analyzed by postoperative computed tomography (CT). Results: Screws with tips located lower (tip I) in the LM did not result in OCJ violation. Only one tip in the tip 3 position showed OCJ perforation, and this screw was also located in tip III. Screw perforation rates of tip 1–tip II, tip 1–tip III, and tip 2–tip III were the highest (100%), followed by tip 2–tip II (10.5%) and tip3–tip III (10%). Conclusion: This study provides insights into OCJ violation during percutaneous ATS fixation. According to AP radiography, a percutaneous ATS with the screw tip located in the lateral part of the LM resulted in a lower rate of OCJ perforation, whereas screws located in the medial LM resulted in the highest rate of perforation. Percutaneous ATS withAbstract : Study Design: A prospective study of anterior transarticular screw (ATS) fixation patients. Objective: To develop a method to determine screw tip position through plain radiography after percutaneous ATS fixation to prevent occipitocervical joint (OCJ) violation. Summary of Background Data: No studies using plain radiography to prevent OCJ violation during percutaneous ATS fixation have been performed. Methods: In total, 34 subjects (with 68 screws) who had undergone percutaneous ATS fixation were enrolled. To evaluate the screw tip location in relation to the C1 lateral mass (LM), the screw tip positions were graded 1, 2, or 3 on anteroposterior (AP) radiographs, and I, II, or III on lateral radiographs. OCJ violation was analyzed by postoperative computed tomography (CT). Results: Screws with tips located lower (tip I) in the LM did not result in OCJ violation. Only one tip in the tip 3 position showed OCJ perforation, and this screw was also located in tip III. Screw perforation rates of tip 1–tip II, tip 1–tip III, and tip 2–tip III were the highest (100%), followed by tip 2–tip II (10.5%) and tip3–tip III (10%). Conclusion: This study provides insights into OCJ violation during percutaneous ATS fixation. According to AP radiography, a percutaneous ATS with the screw tip located in the lateral part of the LM resulted in a lower rate of OCJ perforation, whereas screws located in the medial LM resulted in the highest rate of perforation. Percutaneous ATS with the screw tip located in the neutral part of the LM should ensure that the screw tip is below the upper part of the LM, preventing OCJ violation. These findings may help surgeons assess screw positioning both during and after the operation. Level of Evidence: 3 … (more)
- Is Part Of:
- Spine. Volume 41:Issue 17(2016)
- Journal:
- Spine
- Issue:
- Volume 41:Issue 17(2016)
- Issue Display:
- Volume 41, Issue 17 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 17
- Issue Sort Value:
- 2016-0041-0017-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- occipitocervical joint -- percutaneous anterior transarticular screw -- plain radiography -- screw tip position
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000001508 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1342.xml