Effect of Pelvic Binder Placement on OTA Classification of Pelvic Ring Injuries Using Computed Tomography. Does It Mask the Injury?. Issue 6 (June 2016)
- Record Type:
- Journal Article
- Title:
- Effect of Pelvic Binder Placement on OTA Classification of Pelvic Ring Injuries Using Computed Tomography. Does It Mask the Injury?. Issue 6 (June 2016)
- Main Title:
- Effect of Pelvic Binder Placement on OTA Classification of Pelvic Ring Injuries Using Computed Tomography. Does It Mask the Injury?
- Authors:
- Swartz, John
Vaidya, Rahul
Hudson, Ian
Oliphant, Bryant
Tonnos, Fred - Abstract:
- Abstract : Objectives: To assess the diagnostic sensitivity of computed tomography (CT) in patients with an unstable pelvic ring injury after application of a pelvic binder. Design: An institutional review board approved retrospective study from 2003 to 2010. Setting: Level 1 trauma center. Patients: Inclusion criteria were patients in our trauma database with AO/OTA B or C type pelvic ring injury, which first had an anterior-posterior pelvic x-ray followed by application of a pelvic circumferential compression device (PCCD), then a CT, and a fluoroscopic stress examination under anesthesia (FEUA) (used as gold standard). Of 867 patients, 43 met the inclusion criteria. Intervention: A senior Orthopaedic Resident and Trauma Attendings assessed x-rays, CTs, and FEUAs. Binomial test was used to compare imaging against final diagnosis. Results: In Anterior Posterior Compression/Vertical Shear (OTA 61-B1, 61-B3.1, 61-C) injury patterns, prebinder x-rays were diagnostic in 69.4% (CI, 51.9%–83.7%) of cases, compared with 50% (CI, 32.9%–67.1%) with CT + PCCD. The x-ray was superior to CT + PCCD for identification of the anterior pelvic injury (McNemar exact P = 0.0352). If x-ray and CT + PCCD were viewed in tandem, 83.3% (CI, 67.2%–93.6%) of classifications were in agreement with the FEUA. For lateral compression mechanisms, the binder did not effect of the sensitivity of the CT except in the open book component of an lateral compression 3 (61-B3.2) mechanism. Conclusions: TheAbstract : Objectives: To assess the diagnostic sensitivity of computed tomography (CT) in patients with an unstable pelvic ring injury after application of a pelvic binder. Design: An institutional review board approved retrospective study from 2003 to 2010. Setting: Level 1 trauma center. Patients: Inclusion criteria were patients in our trauma database with AO/OTA B or C type pelvic ring injury, which first had an anterior-posterior pelvic x-ray followed by application of a pelvic circumferential compression device (PCCD), then a CT, and a fluoroscopic stress examination under anesthesia (FEUA) (used as gold standard). Of 867 patients, 43 met the inclusion criteria. Intervention: A senior Orthopaedic Resident and Trauma Attendings assessed x-rays, CTs, and FEUAs. Binomial test was used to compare imaging against final diagnosis. Results: In Anterior Posterior Compression/Vertical Shear (OTA 61-B1, 61-B3.1, 61-C) injury patterns, prebinder x-rays were diagnostic in 69.4% (CI, 51.9%–83.7%) of cases, compared with 50% (CI, 32.9%–67.1%) with CT + PCCD. The x-ray was superior to CT + PCCD for identification of the anterior pelvic injury (McNemar exact P = 0.0352). If x-ray and CT + PCCD were viewed in tandem, 83.3% (CI, 67.2%–93.6%) of classifications were in agreement with the FEUA. For lateral compression mechanisms, the binder did not effect of the sensitivity of the CT except in the open book component of an lateral compression 3 (61-B3.2) mechanism. Conclusions: The placement of a pelvic binder has the potential to mask the severity of unstable pelvic ring injuries when relying only on CT for diagnosis. Fluoroscopic manual pelvic stress examination under anesthesia is an essential adjunct when a binder is placed before imaging. Level of Evidence: Diagnostic level III. See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 30:Issue 6(2016)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 30:Issue 6(2016)
- Issue Display:
- Volume 30, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2016-0030-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-06
- Subjects:
- pelvic injury -- CT -- trauma AP pelvis x-ray -- pelvic binder -- PCCD -- sensitivity -- OTA classification for pelvic fractures -- fluoroscopic pelvic examination -- exam under anesthesia -- false negative
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000000515 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2163.xml