Frölke, Jan Paul - Abstract:
- Abstract : Objectives: To assess the correct positioning of iliosacral screw in patients with unstable traumatic pelvic ring injury by comparing fluoroscopically guided computer-navigated surgery (CNS) with conventional fluoroscopy (CF) through reviewing postoperative computed tomography (CT) and clinical indicators. Design: A comparative multicenter cohort study. Setting: Two level I Trauma Centers in the Netherlands. Patients: The computer-navigated group (n = 56) and the CF group (n = 24) were comparable regarding age (mean, 43 years), sex (58%, male), body mass index (25 kg/m 2 ), injury severity score (27), injury-to-surgery interval (7 days), and Orthopaedic Trauma Association classification (40% 61-B, 60% 61-C). Main Outcome Measurements: The position of the iliosacral screws was evaluated on postoperative CT. In addition, clinical morbidity and reoperation were assessed. Results: In the CNS group, a total of 111 screws were placed (2.0 per patient), of which 83% were placed correctly. In the CF group, 39 screws (1.6 per patient) were placed, 82% of them correctly. Inadequate fixation included neural foramina hit [12 screws (11%) in the CNS group versus 3 screws (8%) in the CF group, P = 0.76] and extraosseous dislocation [7 screws (6%) vs. 4 screws (10%), respectively, P = 0.47]. Five patients required reoperation, all in the CNS group, P = 0.32. We observed more adequate positioning with increased surgical experience, P = 0.12. Conclusions: In contrast to what hasAbstract : Objectives: To assess the correct positioning of iliosacral screw in patients with unstable traumatic pelvic ring injury by comparing fluoroscopically guided computer-navigated surgery (CNS) with conventional fluoroscopy (CF) through reviewing postoperative computed tomography (CT) and clinical indicators. Design: A comparative multicenter cohort study. Setting: Two level I Trauma Centers in the Netherlands. Patients: The computer-navigated group (n = 56) and the CF group (n = 24) were comparable regarding age (mean, 43 years), sex (58%, male), body mass index (25 kg/m 2 ), injury severity score (27), injury-to-surgery interval (7 days), and Orthopaedic Trauma Association classification (40% 61-B, 60% 61-C). Main Outcome Measurements: The position of the iliosacral screws was evaluated on postoperative CT. In addition, clinical morbidity and reoperation were assessed. Results: In the CNS group, a total of 111 screws were placed (2.0 per patient), of which 83% were placed correctly. In the CF group, 39 screws (1.6 per patient) were placed, 82% of them correctly. Inadequate fixation included neural foramina hit [12 screws (11%) in the CNS group versus 3 screws (8%) in the CF group, P = 0.76] and extraosseous dislocation [7 screws (6%) vs. 4 screws (10%), respectively, P = 0.47]. Five patients required reoperation, all in the CNS group, P = 0.32. We observed more adequate positioning with increased surgical experience, P = 0.12. Conclusions: In contrast to what has been suggested by previous studies, we found no benefit from computer-navigated iliosacral screw fixation compared with fluoroscopically guided surgery regarding the correct positioning of iliosacral screw on postoperative CT and related morbidity. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 30:Issue 6(2016)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 30:Issue 6(2016)
- Issue Display:
- Volume 30, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2016-0030-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-06
- Subjects:
- iliosacral -- iliosacral screw -- IS screw -- SI screw -- sacroiliac joint -- computer-navigated surgery -- navigation -- computer-assisted -- conventional fluoroscopy -- fluoroscopy -- computed tomography -- surgery -- OTA -- traumatic -- pelvic ring -- fracture -- pelvic fracture
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000000502 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2163.xml