Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures. Issue 9 (May 2016)
- Record Type:
- Journal Article
- Title:
- Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures. Issue 9 (May 2016)
- Main Title:
- Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures
- Authors:
- Park, Jin Hoon
Kang, Dong-Ho
Lee, Moon Kyu
Yoo, Byoungwoo
Jung, Sang Ku
Hwang, Soo-Hyun
Kim, Jeoung Hee
Oh, Sunkyu
Lee, Eun Jung
Jeon, Sang Ryong
Roh, Sung Woo
Rhim, Seung Chul - Abstract:
- Abstract : Study Design: A retrospective cohort study. Objective: The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. Summary of Background Data: AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. Methods: All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. Results: The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; PAbstract : Study Design: A retrospective cohort study. Objective: The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. Summary of Background Data: AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. Methods: All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. Results: The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Conclusion: Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. Level of Evidence: 3 … (more)
- Is Part Of:
- Spine. Volume 41:Issue 9(2016)
- Journal:
- Spine
- Issue:
- Volume 41:Issue 9(2016)
- Issue Display:
- Volume 41, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 9
- Issue Sort Value:
- 2016-0041-0009-0000
- Page Start:
- E541
- Page End:
- E547
- Publication Date:
- 2016-05
- Subjects:
- anterior odontoid screw -- direction angle -- guide tube -- non-union -- odontoid fracture -- pull out -- rimming -- shallow type III odontoid fracture -- straight probe -- type 2
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000001311 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1615.xml