Impact of Patient Preparation on the Diagnostic Performance of 18F-FDG PET in Cardiac Sarcoidosis: A Systematic Review and Meta-analysis. (July 2016)
- Record Type:
- Journal Article
- Title:
- Impact of Patient Preparation on the Diagnostic Performance of 18F-FDG PET in Cardiac Sarcoidosis: A Systematic Review and Meta-analysis. (July 2016)
- Main Title:
- Impact of Patient Preparation on the Diagnostic Performance of 18F-FDG PET in Cardiac Sarcoidosis
- Authors:
- Tang, Reuben
Wang, Jeffrey Tzu-Yu
Wang, Louis
Le, Ken
Huang, Yeqian
Hickey, Adam James
Emmett, Louise - Abstract:
- Abstract : Purpose: 18 F-FDG PET/CT is a valuable diagnostic tool in the evaluation of cardiac sarcoidosis. Appropriate patient preparation is important because the diagnostic accuracy of this procedure depends on adequate suppression of physiologic glucose uptake. This systematic review and meta-analysis aims to assess the effect of different patient preparations on the diagnostic accuracy of 18 F-FDG PET/CT in cardiac sarcoidosis. Patients and Methods: We searched the PubMed/MEDLINE, Embase, and Cinicaltrials.gov databases. Sixteen studies (n = 559) were identified to be suitable for this systemic review. Studies were stratified according to fasting duration and means of physiologic suppression of 18 F-FDG by cardiac tissue, which involves the use of heparin infusion or high-fat, low-carbohydrate diet before imaging. Study quality was assessed using the QUADAS-2 tool. Forest plots of sensitivity and specificity were calculated in Review Manager 5.3, and a random-effects hierarchical summary receiver operating characteristic model was created using MetaDiSc. Meta-regression was performed to investigate sources of heterogeneity. Results: PET/CT had an overall Specificity of 0.75 (95% confidence interval [CI], 0.69–0.80) and specificity of 0.81 (95% CI, 0.76–0.85) for the diagnosis of cardiac sarcoidosis. This modest diagnostic accuracy was attributed to the inclusion of large single study in which a short fasting duration before scanning likely influenced its sensitivity.Abstract : Purpose: 18 F-FDG PET/CT is a valuable diagnostic tool in the evaluation of cardiac sarcoidosis. Appropriate patient preparation is important because the diagnostic accuracy of this procedure depends on adequate suppression of physiologic glucose uptake. This systematic review and meta-analysis aims to assess the effect of different patient preparations on the diagnostic accuracy of 18 F-FDG PET/CT in cardiac sarcoidosis. Patients and Methods: We searched the PubMed/MEDLINE, Embase, and Cinicaltrials.gov databases. Sixteen studies (n = 559) were identified to be suitable for this systemic review. Studies were stratified according to fasting duration and means of physiologic suppression of 18 F-FDG by cardiac tissue, which involves the use of heparin infusion or high-fat, low-carbohydrate diet before imaging. Study quality was assessed using the QUADAS-2 tool. Forest plots of sensitivity and specificity were calculated in Review Manager 5.3, and a random-effects hierarchical summary receiver operating characteristic model was created using MetaDiSc. Meta-regression was performed to investigate sources of heterogeneity. Results: PET/CT had an overall Specificity of 0.75 (95% confidence interval [CI], 0.69–0.80) and specificity of 0.81 (95% CI, 0.76–0.85) for the diagnosis of cardiac sarcoidosis. This modest diagnostic accuracy was attributed to the inclusion of large single study in which a short fasting duration before scanning likely influenced its sensitivity. Its exclusion resulted in an overall sensitivity of 0.81 (95% CI, 0.76–0.86) and specificity of 0.82 (95% CI, 0.77–0.86). Meta-regression showed that the diagnostic odds ratio was significantly affected by fasting time and heparin administration before scanning ( P = 0.01, 0.02) but not with high-fat, low-carbohydrate diet ( P = 0.17). Conclusions: 18 F-FDG PET/CT plays an integral role in the diagnosis of cardiac sarcoidosis. Diagnostic accuracy is affected by fasting duration and means of cardiomyocyte glucose uptake suppression before scanning. … (more)
- Is Part Of:
- Clinical nuclear medicine. Volume 41:Number 7(2016)
- Journal:
- Clinical nuclear medicine
- Issue:
- Volume 41:Number 7(2016)
- Issue Display:
- Volume 41, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 7
- Issue Sort Value:
- 2016-0041-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-07
- Subjects:
- 18F-FDG PET/CT -- cardiac sarcoidosis -- meta-analysis -- diagnostic accuracy
Nuclear medicine -- Periodicals
Radioisotope scanning -- Periodicals
Nuclear Medicine -- Periodicals
616.07575 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00003072-000000000-00000 ↗
http://journals.lww.com/nuclearmed/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLU.0000000000001063 ↗
- Languages:
- English
- ISSNs:
- 0363-9762
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.314000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1066.xml