Comparison of the yield from two faecal immunochemical tests at identical cutoff concentrations – a randomized trial in Latvia. Issue 8 (August 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of the yield from two faecal immunochemical tests at identical cutoff concentrations – a randomized trial in Latvia. Issue 8 (August 2016)
- Main Title:
- Comparison of the yield from two faecal immunochemical tests at identical cutoff concentrations – a randomized trial in Latvia
- Authors:
- Santare, Daiga
Kojalo, Ilona
Liepniece-Karele, Inta
Kikuste, Ilze
Tolmanis, Ivars
Polaka, Inese
Vikmanis, Uldis
Boka, Viesturs
Leja, Marcis - Abstract:
- Abstract : Objective: We have compared the performance of two faecal immunochemical tests (FIT) in an average-risk population. Materials and methods: Altogether, 10 000 individuals aged 50–74 were selected randomly from the population of Latvia in 2011 and assigned randomly either to OC-Sensor or to FOB Gold single-time testing. Positivity of the test, frequency of colonic lesions, number needed to screen (NNscreen) and scope for the detection of an advanced neoplasm (cancer and advanced adenoma) were compared between the tests using the same cutoff concentrations in µg/g faeces. Confidence intervals (CIs) at 95% were calculated. Results: Positivity with the cutoff set at 10 µg/g faeces was 12.8% (95% CI: 11.4–14.2) for FOB Gold and 8.3% (95% CI: 7.2–9.4) for OC-Sensor ( P <0.001). Positivity was higher in men and the older age groups. Colonoscopy compliance was 55.5%. There was no significant difference between the two tests at comparable cutoff concentrations in µg/g, colonoscopy attendance rate or colonoscopy results. For advanced neoplasm detection, there was no significant difference in number needed to scope and NNscreen at a cutoff of 10 µg/g faeces; however, lower NNscreen was required to detect advanced neoplasms with the FOB Gold test at increased cutoff concentrations. Conclusion: Different quantitative FIT systems may report different positivity rate at identical cutoff concentrations, which has to be considered when implementing the use of FIT in nationalAbstract : Objective: We have compared the performance of two faecal immunochemical tests (FIT) in an average-risk population. Materials and methods: Altogether, 10 000 individuals aged 50–74 were selected randomly from the population of Latvia in 2011 and assigned randomly either to OC-Sensor or to FOB Gold single-time testing. Positivity of the test, frequency of colonic lesions, number needed to screen (NNscreen) and scope for the detection of an advanced neoplasm (cancer and advanced adenoma) were compared between the tests using the same cutoff concentrations in µg/g faeces. Confidence intervals (CIs) at 95% were calculated. Results: Positivity with the cutoff set at 10 µg/g faeces was 12.8% (95% CI: 11.4–14.2) for FOB Gold and 8.3% (95% CI: 7.2–9.4) for OC-Sensor ( P <0.001). Positivity was higher in men and the older age groups. Colonoscopy compliance was 55.5%. There was no significant difference between the two tests at comparable cutoff concentrations in µg/g, colonoscopy attendance rate or colonoscopy results. For advanced neoplasm detection, there was no significant difference in number needed to scope and NNscreen at a cutoff of 10 µg/g faeces; however, lower NNscreen was required to detect advanced neoplasms with the FOB Gold test at increased cutoff concentrations. Conclusion: Different quantitative FIT systems may report different positivity rate at identical cutoff concentrations, which has to be considered when implementing the use of FIT in national screening programmes. … (more)
- Is Part Of:
- European journal of gastroenterology & hepatology. Volume 28:Issue 8(2016:Aug.)
- Journal:
- European journal of gastroenterology & hepatology
- Issue:
- Volume 28:Issue 8(2016:Aug.)
- Issue Display:
- Volume 28, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 28
- Issue:
- 8
- Issue Sort Value:
- 2016-0028-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-08
- Subjects:
- advanced neoplasm -- colonoscopy -- colorectal cancer screening -- cutoff -- faecal immunochemical test
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Digestive organs -- Diseases
Liver -- Diseases
Periodicals
616.33 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00042737-000000000-00000 ↗
http://www.eurojgh.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/MEG.0000000000000650 ↗
- Languages:
- English
- ISSNs:
- 0954-691X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.729400
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2539.xml