Dispatcher-assisted compression-only cardiopulmonary resuscitation provides best quality cardiopulmonary resuscitation by laypersons: A randomised controlled single-blinded manikin trial. Issue 8 (August 2016)
- Record Type:
- Journal Article
- Title:
- Dispatcher-assisted compression-only cardiopulmonary resuscitation provides best quality cardiopulmonary resuscitation by laypersons: A randomised controlled single-blinded manikin trial. Issue 8 (August 2016)
- Main Title:
- Dispatcher-assisted compression-only cardiopulmonary resuscitation provides best quality cardiopulmonary resuscitation by laypersons
- Authors:
- Spelten, Oliver
Warnecke, Tobias
Wetsch, Wolfgang A.
Schier, Robert
Böttiger, Bernd W.
Hinkelbein, Jochen - Abstract:
- Abstract : BACKGROUND: High-quality cardiopulmonary resuscitation (CPR) by laypersons is a key determinant of both outcome and survival for out-of-hospital cardiac arrest. Dispatcher-assisted CPR (telephone-CPR, T-CPR) increases the frequency and correctness of bystander-CPR but results in prolonged time to first chest compressions. However, it remains unclear whether instructions for rescue ventilation and/or chest compressions should be recommended for dispatcher-assisted CPR. OBJECTIVE: The aim of this study was to evaluate both principles of T-CPR with respect to CPR quality. DESIGN: Randomised controlled single-blinded manikin trial. SETTING: University Hospital of Cologne, Germany, 1 July 2012 to 30 September 2012. PARTICIPANTS: Sixty laypersons between 18 and 65 years. Medically educated individuals, medical professionals and pregnant women were excluded. Participants were asked to resuscitate a manikin and were randomised into three groups: not dispatcher-assisted (uninstructed) CPR (group 1; U-CPR; n = 20), dispatcher-assisted compression-only CPR (group 2; DACO-CPR; n = 19) and full dispatcher-assisted CPR with rescue ventilation (group 3; DAF-CPR; n = 19). MAIN OUTCOME MEASURES: Specific parameters of CPR quality [i.e. no-flow-time (NFT) as well as compression and ventilation parameters] were analysed. To compare different groups we used Student's t test and P less than 0.05 was considered significant. RESULTS: Initial NFT was lowest in the DACO-CPR group (meanAbstract : BACKGROUND: High-quality cardiopulmonary resuscitation (CPR) by laypersons is a key determinant of both outcome and survival for out-of-hospital cardiac arrest. Dispatcher-assisted CPR (telephone-CPR, T-CPR) increases the frequency and correctness of bystander-CPR but results in prolonged time to first chest compressions. However, it remains unclear whether instructions for rescue ventilation and/or chest compressions should be recommended for dispatcher-assisted CPR. OBJECTIVE: The aim of this study was to evaluate both principles of T-CPR with respect to CPR quality. DESIGN: Randomised controlled single-blinded manikin trial. SETTING: University Hospital of Cologne, Germany, 1 July 2012 to 30 September 2012. PARTICIPANTS: Sixty laypersons between 18 and 65 years. Medically educated individuals, medical professionals and pregnant women were excluded. Participants were asked to resuscitate a manikin and were randomised into three groups: not dispatcher-assisted (uninstructed) CPR (group 1; U-CPR; n = 20), dispatcher-assisted compression-only CPR (group 2; DACO-CPR; n = 19) and full dispatcher-assisted CPR with rescue ventilation (group 3; DAF-CPR; n = 19). MAIN OUTCOME MEASURES: Specific parameters of CPR quality [i.e. no-flow-time (NFT) as well as compression and ventilation parameters] were analysed. To compare different groups we used Student's t test and P less than 0.05 was considered significant. RESULTS: Initial NFT was lowest in the DACO-CPR group (mean 21.3 ± 14.4%), followed by dispatcher-assisted full CPR (mean 49.1 ± 8.5%) and by unassisted CPR (mean 55.0 ± 12.9%). Initial NFT covering the time of instruction was lower in DACO-CPR (12.1 ± 5.4%) as compared to dispatcher-assisted full CPR (20.7 ± 8.1%). Compression depth was similar in all three groups: 40.6 ± 13.0 mm (unassisted CPR), 41.0 ± 12.2 mm (DACO-CPR) and 38.8 ± 15.8 mm (dispatcher-assisted full CPR). Average compression frequency was highest in the DACO-CPR group (65.2 ± 22.4 min −1 ) compared with the unassisted CPR group (35.6 ± 24.2 min −1 ) and the dispatcher-assisted full CPR group (44.5 ± 10.8 min −1 ). Correct rescue ventilation was given in 3.1 ± 11.1% (unassisted CPR) and 1.6 ± 16.1% (dispatcher-assisted full CPR) of all ventilation attempts. CONCLUSION: Best quality of CPR was achieved by DACO-CPR because of superior compression frequencies and reduced NFT. In contrast, the full dispatcher-assisted CPR with a longer initial instructing phase (initial NFT) did not result in enhanced CPR quality or an optimised compression depth. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- European journal of anaesthesiology. Volume 33:Issue 8(2016:Aug.)
- Journal:
- European journal of anaesthesiology
- Issue:
- Volume 33:Issue 8(2016:Aug.)
- Issue Display:
- Volume 33, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 33
- Issue:
- 8
- Issue Sort Value:
- 2016-0033-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-08
- Subjects:
- Anesthesiology -- Periodicals
Anesthesiology -- Periodicals
Anesthésiologie -- Périodiques
Anesthesiology
Periodicals
Electronic journals
617.96 - Journal URLs:
- http://journals.lww.com/ejanaesthesiology/pages/default.aspx ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2346/issues ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=eja ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00003643-000000000-00000 ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0265-0215 ↗ - DOI:
- 10.1097/EJA.0000000000000432 ↗
- Languages:
- English
- ISSNs:
- 0265-0215
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.722200
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 433.xml