Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms. Issue 6 (June 2016)
- Record Type:
- Journal Article
- Title:
- Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms. Issue 6 (June 2016)
- Main Title:
- Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms
- Authors:
- John, Seby
Bain, Mark D.
Hui, Ferdinand K.
Hussain, M. Shazam
Masaryk, Thomas J.
Rasmussen, Peter A.
Toth, Gabor - Abstract:
- Abstract : BACKGROUND: There is scant information on in-stent stenosis after flow diversion treatment of intracranial aneurysms with the Pipeline Embolization Device (PED). OBJECTIVE: To assess the incidence, severity, nature, and clinical consequences of in-stent stenosis on angiographic follow-up after treatment with the PED. METHODS: A retrospective study of patients who underwent aneurysm treatment with the PED was conducted. In-stent stenosis was assessed on subsequent follow-up angiography. Intimal hyperplasia was defined as a uniform growth process beyond the limits of the metallic mesh at <25%. In-stent stenosis represented an area of parent vessel narrowing, most often focal, graded as mild (25%-50%), moderate (50%-75%), or severe (>75%). RESULTS: Between June 2011 and April 2015, 80 patients were treated with the PED. Angiographic follow-up was available for 51 patients (representing 76% of available or 64% of all patients). Mean follow-up was 12.5 months. In-stent stenosis was detected in 5 patients (9.8%) at a median of 6 months. Stenosis was mild in 4 of 5 (80%) and moderate in 1 of 5 (20%) patients. There were no cases of severe stenosis. No stenosis caused flow limitation, clinical symptoms, or required re-treatment. Additional follow-up angiography was available in 2 of 5 stenosis patients showing marked improvement. Sixteen patients (31%) had intimal hyperplasia, and 28 patients (55%) had no stenosis. Asymptomatic stent occlusion occurred in 2 patients (4%)Abstract : BACKGROUND: There is scant information on in-stent stenosis after flow diversion treatment of intracranial aneurysms with the Pipeline Embolization Device (PED). OBJECTIVE: To assess the incidence, severity, nature, and clinical consequences of in-stent stenosis on angiographic follow-up after treatment with the PED. METHODS: A retrospective study of patients who underwent aneurysm treatment with the PED was conducted. In-stent stenosis was assessed on subsequent follow-up angiography. Intimal hyperplasia was defined as a uniform growth process beyond the limits of the metallic mesh at <25%. In-stent stenosis represented an area of parent vessel narrowing, most often focal, graded as mild (25%-50%), moderate (50%-75%), or severe (>75%). RESULTS: Between June 2011 and April 2015, 80 patients were treated with the PED. Angiographic follow-up was available for 51 patients (representing 76% of available or 64% of all patients). Mean follow-up was 12.5 months. In-stent stenosis was detected in 5 patients (9.8%) at a median of 6 months. Stenosis was mild in 4 of 5 (80%) and moderate in 1 of 5 (20%) patients. There were no cases of severe stenosis. No stenosis caused flow limitation, clinical symptoms, or required re-treatment. Additional follow-up angiography was available in 2 of 5 stenosis patients showing marked improvement. Sixteen patients (31%) had intimal hyperplasia, and 28 patients (55%) had no stenosis. Asymptomatic stent occlusion occurred in 2 patients (4%) related to medication noncompliance. CONCLUSION: Treatment with the PED was associated with a 9.8% rate of in-stent stenosis, detected on first angiographic follow-up, at a median of 6 months. None were symptomatic or required re-treatment, and they showed significant improvement on follow-up. ABBREVIATION: FD, flow diverter … (more)
- Is Part Of:
- Neurosurgery. Volume 78:Issue 6(2016)
- Journal:
- Neurosurgery
- Issue:
- Volume 78:Issue 6(2016)
- Issue Display:
- Volume 78, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 78
- Issue:
- 6
- Issue Sort Value:
- 2016-0078-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-06
- Subjects:
- Flow diverter -- In-stent stenosis -- Intracranial aneurysm -- Pipeline
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1227/NEU.0000000000001146 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 626.xml