Multicenter evaluation of single-photon emission computed tomography quantification with third-party reconstruction software. Issue 9 (September 2016)
- Record Type:
- Journal Article
- Title:
- Multicenter evaluation of single-photon emission computed tomography quantification with third-party reconstruction software. Issue 9 (September 2016)
- Main Title:
- Multicenter evaluation of single-photon emission computed tomography quantification with third-party reconstruction software
- Authors:
- Kangasmaa, Tuija S.
Constable, Chris
Hippeläinen, Eero
Sohlberg, Antti O. - Abstract:
- Abstract : Reliable and reproducible quantification is essential in many clinical situations. Previously, single-photon emission computed tomography (SPECT) has not been considered a quantitative imaging modality, but recent advances in reconstruction algorithm development have made SPECT quantitative. In this study, we investigate the reproducibility of SPECT quantification with phantoms in a multicenter setting using novel third-party reconstruction software. A total of five hospitals and eight scanners (three GE scanners and five Siemens scanners) participated in the study. A Jaszczak phantom without inserts was used to calculate counts to activity concentration conversion factors. The quantitative accuracy was tested using the NEMA-IEC phantom with six spherical inserts (diameters from 10 to 37 mm) filled to an 8 : 1 insert-background concentration ratio. Phantom studies were reconstructed at one central location using HERMES HybridRecon applying corrections for attenuation, collimator-detector response, and scatter. Spherical volumes of interest with the same diameter as the inserts were drawn on the images and recovery coefficients for the spheres were calculated. The coefficient of variation (CoV) of the NEMA-IEC phantom recovery coefficients ranged from ∼19 to 5% depending on the insert diameter so that the lowest CoV was obtained with the largest spheres. The intersite CoV was almost equal to intrasite CoV. In conclusion, quantitative SPECT is reproducible in aAbstract : Reliable and reproducible quantification is essential in many clinical situations. Previously, single-photon emission computed tomography (SPECT) has not been considered a quantitative imaging modality, but recent advances in reconstruction algorithm development have made SPECT quantitative. In this study, we investigate the reproducibility of SPECT quantification with phantoms in a multicenter setting using novel third-party reconstruction software. A total of five hospitals and eight scanners (three GE scanners and five Siemens scanners) participated in the study. A Jaszczak phantom without inserts was used to calculate counts to activity concentration conversion factors. The quantitative accuracy was tested using the NEMA-IEC phantom with six spherical inserts (diameters from 10 to 37 mm) filled to an 8 : 1 insert-background concentration ratio. Phantom studies were reconstructed at one central location using HERMES HybridRecon applying corrections for attenuation, collimator-detector response, and scatter. Spherical volumes of interest with the same diameter as the inserts were drawn on the images and recovery coefficients for the spheres were calculated. The coefficient of variation (CoV) of the NEMA-IEC phantom recovery coefficients ranged from ∼19 to 5% depending on the insert diameter so that the lowest CoV was obtained with the largest spheres. The intersite CoV was almost equal to intrasite CoV. In conclusion, quantitative SPECT is reproducible in a multicenter setting with third-party reconstruction software. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 37:Issue 9(2016:Sep.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 37:Issue 9(2016:Sep.)
- Issue Display:
- Volume 37, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 9
- Issue Sort Value:
- 2016-0037-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- IEC-NEMA phantom -- multicenter -- quantitative-single-photon emission computed tomography
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000538 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2626.xml