Boston Type 1 Keratoprosthesis: Visual Outcomes, Device Retention, and Complications. Issue 9 (September 2016)
- Record Type:
- Journal Article
- Title:
- Boston Type 1 Keratoprosthesis: Visual Outcomes, Device Retention, and Complications. Issue 9 (September 2016)
- Main Title:
- Boston Type 1 Keratoprosthesis
- Authors:
- Goins, Kenneth M.
Kitzmann, Anna S.
Greiner, Mark A.
Kwon, Young H.
Alward, Wallace L. M.
Ledolter, Johannes
Wagoner, Michael D. - Abstract:
- Abstract : Purpose: To determine the visual outcomes, device retention, and complications after Boston type 1 keratoprosthesis (KPro-1) device implantation. Methods: Comprehensive review of every case of KPro-1 implantation at a tertiary eye care center. Results: The initial KPro-1 procedure, performed in 75 eyes without a previous keratoprosthesis, was included in the analysis. During the first 6 postoperative months, improvement occurred in the mean preoperative best-corrected visual acuity of 20/1265 to a mean best-obtained postoperative visual acuity of 20/97 ( P < 0.001). After a mean follow-up period of 41.4 months (range, 0.8–82.8 months), the final mean best-corrected visual acuity was 20/428. Improved vision was recorded in 43 eyes (57.3%), ambulatory vision (≥20/400) in 47 eyes (62.7%), intermediate functional vision (≥20/80) in 23 eyes (30.7%), and full functional vision (≥20/40) in 11 eyes (14.7%). The initial device was retained in 64 eyes (85.3%), with a Kaplan–Meier retention probability of 96% at 6 months and 82% at 5 years. One or more sight-threatening complications occurred in 51 eyes (68%). These included device extrusion in 11 eyes (14.7%), ulcerative keratitis in 12 eyes (16%), endophthalmitis in 7 eyes (9.3%), sterile vitritis in 3 eyes (4%), retroprosthetic membranes in 25 eyes (33.3%), maculopathy in 26 eyes (34.7%), retinal detachment in 9 eyes (12%), and progressive optic neuropathy in 7 eyes (9.3%). Conclusions: Boston KPro-1 implantation isAbstract : Purpose: To determine the visual outcomes, device retention, and complications after Boston type 1 keratoprosthesis (KPro-1) device implantation. Methods: Comprehensive review of every case of KPro-1 implantation at a tertiary eye care center. Results: The initial KPro-1 procedure, performed in 75 eyes without a previous keratoprosthesis, was included in the analysis. During the first 6 postoperative months, improvement occurred in the mean preoperative best-corrected visual acuity of 20/1265 to a mean best-obtained postoperative visual acuity of 20/97 ( P < 0.001). After a mean follow-up period of 41.4 months (range, 0.8–82.8 months), the final mean best-corrected visual acuity was 20/428. Improved vision was recorded in 43 eyes (57.3%), ambulatory vision (≥20/400) in 47 eyes (62.7%), intermediate functional vision (≥20/80) in 23 eyes (30.7%), and full functional vision (≥20/40) in 11 eyes (14.7%). The initial device was retained in 64 eyes (85.3%), with a Kaplan–Meier retention probability of 96% at 6 months and 82% at 5 years. One or more sight-threatening complications occurred in 51 eyes (68%). These included device extrusion in 11 eyes (14.7%), ulcerative keratitis in 12 eyes (16%), endophthalmitis in 7 eyes (9.3%), sterile vitritis in 3 eyes (4%), retroprosthetic membranes in 25 eyes (33.3%), maculopathy in 26 eyes (34.7%), retinal detachment in 9 eyes (12%), and progressive optic neuropathy in 7 eyes (9.3%). Conclusions: Boston KPro-1 implantation is associated with satisfactory visual outcomes and excellent device retention in a majority of cases. However, serious postoperative complications are common and may compromise the final visual result. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Cornea. Volume 35:Issue 9(2016)
- Journal:
- Cornea
- Issue:
- Volume 35:Issue 9(2016)
- Issue Display:
- Volume 35, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 35
- Issue:
- 9
- Issue Sort Value:
- 2016-0035-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- keratoprosthesis -- vision -- device retention -- complications
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000000886 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1318.xml