Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies. Issue 7 (July 2016)
- Record Type:
- Journal Article
- Title:
- Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies. Issue 7 (July 2016)
- Main Title:
- Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies
- Authors:
- Papaioannou, Theodore G.
Karageorgopoulou, Theofani D.
Sergentanis, Theodoros N.
Protogerou, Athanase D.
Psaltopoulou, Theodora
Sharman, James E.
Weber, Thomas
Blacher, Jacques
Daskalopoulou, Stella S.
Wassertheurer, Siegfried
Khir, Ashraf W.
Vlachopoulos, Charalambos
Stergiopulos, Nikolaos
Stefanadis, Christodoulos
Nichols, Wilmer W.
Tousoulis, Dimitrios - Abstract:
- Abstract : Supplemental Digital Content is available in the text Abstract : Background: Although compelling evidence has established the physiological and clinical relevance of aortic SBP (a-SBP), no consensus exists regarding the validity of the available methods/techniques that noninvasively measure it. Objectives: The systematic review and meta-analysis aimed to determine the accuracy of commercial devices estimating a-SBP noninvasively, which have been validated by invasive measurement of a-SBP. Moreover their optimal mode of application, in terms of calibration, as well as specific technique and arterial site of pulse wave acquisition were further investigated. Methods: The study was performed according to the PRISMA guidelines; 22 eligible studies were included, which validated invasively 11 different commercial devices in 808 study participants. Results: Overall, the error in a-SBP estimation (estimated minus actual value) was −4.49 mmHg [95% confidence interval (CI): −6.06 to −2.92 mmHg]. The estimated (noninvasive) a-SBP differed from the actual (invasive) value depending on calibration method: by −1.08 mmHg (95% CI: −2.81, 0.65 mmHg) and by −5.81 mmHg (95% CI: −7.79, −3.84 mmHg), when invasively and noninvasively measured brachial BP values were used respectively; by −1.83 mmHg, (95% CI: −3.32, −0.34 mmHg), and by 7.78 mmHg (95% CI: −10.28, −5.28 mmHg), when brachial mean arterial pressure/DBP and SBP/DBP were used, respectively. Conclusion: Automated recording ofAbstract : Supplemental Digital Content is available in the text Abstract : Background: Although compelling evidence has established the physiological and clinical relevance of aortic SBP (a-SBP), no consensus exists regarding the validity of the available methods/techniques that noninvasively measure it. Objectives: The systematic review and meta-analysis aimed to determine the accuracy of commercial devices estimating a-SBP noninvasively, which have been validated by invasive measurement of a-SBP. Moreover their optimal mode of application, in terms of calibration, as well as specific technique and arterial site of pulse wave acquisition were further investigated. Methods: The study was performed according to the PRISMA guidelines; 22 eligible studies were included, which validated invasively 11 different commercial devices in 808 study participants. Results: Overall, the error in a-SBP estimation (estimated minus actual value) was −4.49 mmHg [95% confidence interval (CI): −6.06 to −2.92 mmHg]. The estimated (noninvasive) a-SBP differed from the actual (invasive) value depending on calibration method: by −1.08 mmHg (95% CI: −2.81, 0.65 mmHg) and by −5.81 mmHg (95% CI: −7.79, −3.84 mmHg), when invasively and noninvasively measured brachial BP values were used respectively; by −1.83 mmHg, (95% CI: −3.32, −0.34 mmHg), and by 7.78 mmHg (95% CI: −10.28, −5.28 mmHg), when brachial mean arterial pressure/DBP and SBP/DBP were used, respectively. Conclusion: Automated recording of waveforms, calibrated noninvasively by brachial mean arterial pressure/DBP values seems the most promising approach that can provide relatively more accurate, noninvasive estimation of a-SBP. It is still uncertain whether a specific device can be recommended as 'gold standard'; however, a consensus is currently demanding. … (more)
- Is Part Of:
- Journal of hypertension. Volume 34:Issue 7(2016:Jul.)
- Journal:
- Journal of hypertension
- Issue:
- Volume 34:Issue 7(2016:Jul.)
- Issue Display:
- Volume 34, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 34
- Issue:
- 7
- Issue Sort Value:
- 2016-0034-0007-0000
- Page Start:
- 1237
- Page End:
- 1248
- Publication Date:
- 2016-07
- Subjects:
- accuracy -- aortic hemodynamics -- applanation tonometry -- calibration -- fluid-filled catheter manometer systems -- micro-tip pressure transducers -- oscillometry -- pressure wave -- pulse wave analysis -- transfer functions
Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/HJH.0000000000000921 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1635.xml