Cone Beam CT Versus Multislice CT: Radiologic Diagnostic Agreement in the Postoperative Assessment of Cochlear Implantation. Issue 9 (October 2016)
- Record Type:
- Journal Article
- Title:
- Cone Beam CT Versus Multislice CT: Radiologic Diagnostic Agreement in the Postoperative Assessment of Cochlear Implantation. Issue 9 (October 2016)
- Main Title:
- Cone Beam CT Versus Multislice CT
- Authors:
- Razafindranaly, Victor
Truy, Eric
Pialat, Jean-Baptiste
Martinon, Amanda
Bourhis, Magali
Boublay, Nawele
Faure, Frédéric
Ltaïef-Boudrigua, Aïcha - Abstract:
- Abstract : Objective: To evaluate the diagnostic concordance between multislice computed tomography (MSCT) and cone beam computed tomography (CBCT) in the early postoperative assessment of patients after cochlear implantation. Study Design: Prospective, randomized, single-center, interventional, pilot study on the diagnostic performance of a medical device. Setting: Tertiary referral center. Patients: Patients aged over 18 years requiring a computed tomographic (CT) scan after cochlear implant surgery. Interventions: Nine patients were implanted with electrode arrays from three different manufacturers, including one bilateral. High-resolution MSCT and CBCT were then performed, and two experienced radiologists blinded to the imaging modality evaluated the randomized images, twice. Main Outcome Measures: Concordance between MSCT and CBCT for assessing the scalar position (tympani or vestibuli) of the electrodes. Secondary outcome measures were also studied: length of the intracochlear electrode array, percentage of implanted cochlea, number of intracochlear electrodes, and radiation doses. Results: There was a good agreement between both CT scanners in determining the scalar position and estimating the number of implanted electrodes and percentage of implanted cochlea. CBCT had a lower radiation exposure. Conclusions: The CBCT appears to be a useful tool for postoperative assessment of cochlear implanted adult patients and is comparable to the conventional scanner inAbstract : Objective: To evaluate the diagnostic concordance between multislice computed tomography (MSCT) and cone beam computed tomography (CBCT) in the early postoperative assessment of patients after cochlear implantation. Study Design: Prospective, randomized, single-center, interventional, pilot study on the diagnostic performance of a medical device. Setting: Tertiary referral center. Patients: Patients aged over 18 years requiring a computed tomographic (CT) scan after cochlear implant surgery. Interventions: Nine patients were implanted with electrode arrays from three different manufacturers, including one bilateral. High-resolution MSCT and CBCT were then performed, and two experienced radiologists blinded to the imaging modality evaluated the randomized images, twice. Main Outcome Measures: Concordance between MSCT and CBCT for assessing the scalar position (tympani or vestibuli) of the electrodes. Secondary outcome measures were also studied: length of the intracochlear electrode array, percentage of implanted cochlea, number of intracochlear electrodes, and radiation doses. Results: There was a good agreement between both CT scanners in determining the scalar position and estimating the number of implanted electrodes and percentage of implanted cochlea. CBCT had a lower radiation exposure. Conclusions: The CBCT appears to be a useful tool for postoperative assessment of cochlear implanted adult patients and is comparable to the conventional scanner in determining the scalar position, with lower radiation exposure. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Otology & neurotology. Volume 37:Issue 9(2016)
- Journal:
- Otology & neurotology
- Issue:
- Volume 37:Issue 9(2016)
- Issue Display:
- Volume 37, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 9
- Issue Sort Value:
- 2016-0037-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-10
- Subjects:
- Cochlear implant -- Cone beam computed tomography -- Digital volume tomography -- Flat panel computed tomography -- Multislice computed tomography -- Scalar localization
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000001165 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 932.xml