Computed Tomography Estimation of Cochlear Duct Length Can Predict Full Insertion in Cochlear Implantation. Issue 3 (March 2016)
- Record Type:
- Journal Article
- Title:
- Computed Tomography Estimation of Cochlear Duct Length Can Predict Full Insertion in Cochlear Implantation. Issue 3 (March 2016)
- Main Title:
- Computed Tomography Estimation of Cochlear Duct Length Can Predict Full Insertion in Cochlear Implantation
- Authors:
- Johnston, James D. A.
Scoffings, Daniel
Chung, Mark
Baguley, David
Donnelly, Neil P.
Axon, Patrick R.
Gray, Roger F.
Tysome, James R. - Abstract:
- Abstract : Objective: To compare the rates of full insertion of electrodes and hearing outcomes obtained with 28-mm and 31-mm cochlear implant electrode arrays. To assess whether cochlear duct length (CDL) estimated by preoperative computed tomography (CT) predicts whether an electrode is fully inserted. Study Design: A cohort study compared electrodes inserted and hearing outcomes after implantation with 28-mm or 31-mm arrays. CDL estimated from preoperative CT was compared in patients in whom full insertion of the 28-mm array was achieved compared with patients in whom at least one basal electrode was outside the cochlea. Setting: Tertiary referral cochlear implantation center. Patients: One hundred forty-eight patients implanted with 28-mm cochlear implant arrays (175 devices) and 74 patients implanted with 31-mm arrays (88 devices). Intervention: Cochlear implantation with 28-mm or 31-mm array. Main Outcome Measures: : Active electrodes at first programming, and at subsequent follow-ups. Bamford–Kowal–Bench sentence and auditory speech sound evaluation test results at 2 to 3 months in adult patients. CDL predicted by preoperative CT. Results: There was no difference in full insertion between the 28-mm and 31-mm array cohorts ( p = 0.22). Early hearing outcomes at 2 to 3 months showed no difference in mean auditory speech sound evaluation ( p = 0.19) or Bamford–Kowal–Bench results ( p = 0.853) between the 28-mm and 31-mm cohorts. CDL was shorter in the 22 patients withAbstract : Objective: To compare the rates of full insertion of electrodes and hearing outcomes obtained with 28-mm and 31-mm cochlear implant electrode arrays. To assess whether cochlear duct length (CDL) estimated by preoperative computed tomography (CT) predicts whether an electrode is fully inserted. Study Design: A cohort study compared electrodes inserted and hearing outcomes after implantation with 28-mm or 31-mm arrays. CDL estimated from preoperative CT was compared in patients in whom full insertion of the 28-mm array was achieved compared with patients in whom at least one basal electrode was outside the cochlea. Setting: Tertiary referral cochlear implantation center. Patients: One hundred forty-eight patients implanted with 28-mm cochlear implant arrays (175 devices) and 74 patients implanted with 31-mm arrays (88 devices). Intervention: Cochlear implantation with 28-mm or 31-mm array. Main Outcome Measures: : Active electrodes at first programming, and at subsequent follow-ups. Bamford–Kowal–Bench sentence and auditory speech sound evaluation test results at 2 to 3 months in adult patients. CDL predicted by preoperative CT. Results: There was no difference in full insertion between the 28-mm and 31-mm array cohorts ( p = 0.22). Early hearing outcomes at 2 to 3 months showed no difference in mean auditory speech sound evaluation ( p = 0.19) or Bamford–Kowal–Bench results ( p = 0.853) between the 28-mm and 31-mm cohorts. CDL was shorter in the 22 patients with less than full insertion of the array with a mean length of 28.7 mm compared with 29.6 mm in the 42 patients in whom full insertion was achieved ( p = 0.046). Conclusion: CT estimation of CDL predicts full insertion after cochlear implantation. Insertion depth does not affect early hearing outcome. … (more)
- Is Part Of:
- Otology & neurotology. Volume 37:Issue 3(2016)
- Journal:
- Otology & neurotology
- Issue:
- Volume 37:Issue 3(2016)
- Issue Display:
- Volume 37, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 3
- Issue Sort Value:
- 2016-0037-0003-0000
- Page Start:
- 223
- Page End:
- 228
- Publication Date:
- 2016-03
- Subjects:
- Cochlear duct length -- Cochlear implant -- Computed tomography
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000000955 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 850.xml