Localization of Interictal Epileptic Spikes With MEG: Optimization of an Automated Beamformer Screening Method (SAMepi) in a Diverse Epilepsy Population. Issue 5 (October 2016)
- Record Type:
- Journal Article
- Title:
- Localization of Interictal Epileptic Spikes With MEG: Optimization of an Automated Beamformer Screening Method (SAMepi) in a Diverse Epilepsy Population. Issue 5 (October 2016)
- Main Title:
- Localization of Interictal Epileptic Spikes With MEG
- Authors:
- Scott, Jonathan M.
Robinson, Stephen E.
Holroyd, Tom
Coppola, Richard
Sato, Susumu
Inati, Sara K. - Abstract:
- Abstract : Purpose: To describe and optimize an automated beamforming technique followed by identification of locations with excess kurtosis (g2) for efficient detection and localization of interictal spikes in patients with medically refractory epilepsy. Methods: Synthetic aperture magnetometry with g2 averaged over a sliding time window (SAMepi) was performed in seven patients with focal epilepsy and five healthy volunteers. The effect of varied window lengths on detection of spiking activity was evaluated. Results: Sliding window lengths of 0.5 to 10 seconds performed similarly, with 0.5- and 1-second windows detecting spiking activity in 1 of the 3 virtual sensor locations with highest kurtosis. These locations were concordant with the region of eventual surgical resection in these seven patients who remained seizure-free at 1 year. Average g2 values increased with increasing sliding window length in all subjects. In healthy volunteers, kurtosis values stabilized in data sets longer than 2 minutes. Conclusions: SAMepi using g2 averaged over 1-second sliding time windows in data sets of at least 2 minutes of duration reliably identified interictal spiking and the presumed seizure focus in these seven patients. Screening the five locations with highest kurtosis values for spiking activity is an efficient and accurate technique for localizing interictal activity using magnetoencephalography. Significance: SAMepi should be applied using the parameter values and procedureAbstract : Purpose: To describe and optimize an automated beamforming technique followed by identification of locations with excess kurtosis (g2) for efficient detection and localization of interictal spikes in patients with medically refractory epilepsy. Methods: Synthetic aperture magnetometry with g2 averaged over a sliding time window (SAMepi) was performed in seven patients with focal epilepsy and five healthy volunteers. The effect of varied window lengths on detection of spiking activity was evaluated. Results: Sliding window lengths of 0.5 to 10 seconds performed similarly, with 0.5- and 1-second windows detecting spiking activity in 1 of the 3 virtual sensor locations with highest kurtosis. These locations were concordant with the region of eventual surgical resection in these seven patients who remained seizure-free at 1 year. Average g2 values increased with increasing sliding window length in all subjects. In healthy volunteers, kurtosis values stabilized in data sets longer than 2 minutes. Conclusions: SAMepi using g2 averaged over 1-second sliding time windows in data sets of at least 2 minutes of duration reliably identified interictal spiking and the presumed seizure focus in these seven patients. Screening the five locations with highest kurtosis values for spiking activity is an efficient and accurate technique for localizing interictal activity using magnetoencephalography. Significance: SAMepi should be applied using the parameter values and procedure described for optimal detection and localization of interictal spikes. Use of this screening procedure could significantly improve the efficiency of magnetoencephalography analysis if clinically validated. … (more)
- Is Part Of:
- Journal of clinical neurophysiology. Volume 33:Issue 5(2016)
- Journal:
- Journal of clinical neurophysiology
- Issue:
- Volume 33:Issue 5(2016)
- Issue Display:
- Volume 33, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 33
- Issue:
- 5
- Issue Sort Value:
- 2016-0033-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-10
- Subjects:
- Magnetoencephalography -- Source localization -- Epilepsy -- Beamforming -- Kurtosis
Electroencephalography -- Periodicals
Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electroencephalography
Periodicals
612.805 - Journal URLs:
- http://journals.lww.com/clinicalneurophys/pages/default.aspx ↗
http://www.clinicalneurophys.com ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00004691-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/WNP.0000000000000255 ↗
- Languages:
- English
- ISSNs:
- 0736-0258
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.578000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2507.xml