Intraoperative Real-time Cochlear Response Telemetry Predicts Hearing Preservation in Cochlear Implantation. Issue 4 (April 2016)
- Record Type:
- Journal Article
- Title:
- Intraoperative Real-time Cochlear Response Telemetry Predicts Hearing Preservation in Cochlear Implantation. Issue 4 (April 2016)
- Main Title:
- Intraoperative Real-time Cochlear Response Telemetry Predicts Hearing Preservation in Cochlear Implantation
- Authors:
- Campbell, Luke
Kaicer, Arielle
Sly, David
Iseli, Claire
Wei, Benjamin
Briggs, Robert
O'Leary, Stephen - Abstract:
- Abstract : Aim: To monitor cochlear function during cochlear implantation and determine correlations with postoperative acoustic hearing. Background: Cochlear response telemetry measures cochlear function directly from cochlear implant electrodes. We have adapted this system to provide real-time cochlear response telemetry (RT-CRT) monitoring of a patient's acoustic hearing as the cochlear implant electrode array is inserted. Methods: Eighteen subjects (1 child and 17 adults) with sloping high frequency hearing loss were implanted with Cochlear Ltd slim straight arrays (CI422/CI522). Tone bursts (500 Hz, 100–110 dB) were presented at 14 Hz continuously during the array insertion. RT-CRT amplitudes were correlated with surgical manoeuvres recorded on the video from the operating microscope and with postoperative pure tone audiograms. Results: Despite an excellent overall rate of complete or partial hearing preservation (79%), RT-CRT identified that in 47% of these implantations there was transient or permanent reduction in the amplitude of the cochlear microphonic (CM). Patients with a preserved CM at the end of insertion had on average 15 dB better low-frequency hearing preservation. The CM amplitude was most vulnerable during the last few millimeters of insertion or when inadvertent movement of the array occurred after full insertion. Physical contact/elevation of the basilar membrane is hypothesized as a likely mechanism of hearing loss rather than overt physical trauma.Abstract : Aim: To monitor cochlear function during cochlear implantation and determine correlations with postoperative acoustic hearing. Background: Cochlear response telemetry measures cochlear function directly from cochlear implant electrodes. We have adapted this system to provide real-time cochlear response telemetry (RT-CRT) monitoring of a patient's acoustic hearing as the cochlear implant electrode array is inserted. Methods: Eighteen subjects (1 child and 17 adults) with sloping high frequency hearing loss were implanted with Cochlear Ltd slim straight arrays (CI422/CI522). Tone bursts (500 Hz, 100–110 dB) were presented at 14 Hz continuously during the array insertion. RT-CRT amplitudes were correlated with surgical manoeuvres recorded on the video from the operating microscope and with postoperative pure tone audiograms. Results: Despite an excellent overall rate of complete or partial hearing preservation (79%), RT-CRT identified that in 47% of these implantations there was transient or permanent reduction in the amplitude of the cochlear microphonic (CM). Patients with a preserved CM at the end of insertion had on average 15 dB better low-frequency hearing preservation. The CM amplitude was most vulnerable during the last few millimeters of insertion or when inadvertent movement of the array occurred after full insertion. Physical contact/elevation of the basilar membrane is hypothesized as a likely mechanism of hearing loss rather than overt physical trauma. Conclusion: RT-CRT can be used to predict early postoperative hearing loss and to potentially refine surgical technique. In the future, feedback of RT-CRT may prove to be a valuable tool for maximizing preservation of residual hearing or providing feedback on electrode contact with the basilar membrane. … (more)
- Is Part Of:
- Otology & neurotology. Volume 37:Issue 4(2016)
- Journal:
- Otology & neurotology
- Issue:
- Volume 37:Issue 4(2016)
- Issue Display:
- Volume 37, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 4
- Issue Sort Value:
- 2016-0037-0004-0000
- Page Start:
- 332
- Page End:
- 338
- Publication Date:
- 2016-04
- Subjects:
- Cochlear implant -- Cochlear response telemetry -- CRT -- Electroacoustic stimulation -- Electrocochleography -- Hearing preservation -- Monitoring
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000000972 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1342.xml