Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients. Issue 5 (September 2016)
- Record Type:
- Journal Article
- Title:
- Comparative Effectiveness of Dialyzers: A Longitudinal, Propensity Score-Matched Study of Incident Hemodialysis Patients. Issue 5 (September 2016)
- Main Title:
- Comparative Effectiveness of Dialyzers
- Authors:
- Sibbel, Scott
Hunt, Abigail
Laplante, Suzanne
Beck, Werner
Gellens, Mary
Brunelli, Steven M. - Abstract:
- Abstract : Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1, 2009, and December 31, 2013, and using polyarylethersulfone–polyvinylpyrrolidone (PAS-PVP; Polyflux Revaclear) or polysulfone (PS; Optiflux 160 or Optiflux 180) dialyzers were followed for 1 year or until end of study or censoring for dialyzer switch, modality change, or loss to follow-up. For each comparison, eligible patients were propensity score-matched 1:1 on a range of baseline characteristics. Outcomes were assessed using generalized linear mixed models. Dialysis adequacy was similar in both dialyzer groups. Erythropoiesis-stimulating agent (ESA) doses were lower for patients using PAS-PVP versus patients using PS-160 (difference range: 75–589 units/treatment; statistically significant in months 1–5 and 7) and for patients using PAS-PVP versus patients using PS-180 (difference range: 27–591 unit/treatment; statistically significant in months 1–9). Intravenous iron doses trended lower for patients using PAS-PVP versus patients using PS, but hemoglobin concentrations were equivalent. In conclusion, use of PAS-PVP versus PS dialyzers was associated with equivalent dialysis adequacy, lower ESA doses, modestly lower Intravenous iron doses, and equivalent hemoglobinAbstract : Differences in dialyzer design may have consequences for patient outcomes. We evaluated the comparative effectiveness of commonly used dialyzers with respect to measures of dialysis treatment, anemia management, inflammation, and dialyzer clotting. Patients receiving hemodialysis between January 1, 2009, and December 31, 2013, and using polyarylethersulfone–polyvinylpyrrolidone (PAS-PVP; Polyflux Revaclear) or polysulfone (PS; Optiflux 160 or Optiflux 180) dialyzers were followed for 1 year or until end of study or censoring for dialyzer switch, modality change, or loss to follow-up. For each comparison, eligible patients were propensity score-matched 1:1 on a range of baseline characteristics. Outcomes were assessed using generalized linear mixed models. Dialysis adequacy was similar in both dialyzer groups. Erythropoiesis-stimulating agent (ESA) doses were lower for patients using PAS-PVP versus patients using PS-160 (difference range: 75–589 units/treatment; statistically significant in months 1–5 and 7) and for patients using PAS-PVP versus patients using PS-180 (difference range: 27–591 unit/treatment; statistically significant in months 1–9). Intravenous iron doses trended lower for patients using PAS-PVP versus patients using PS, but hemoglobin concentrations were equivalent. In conclusion, use of PAS-PVP versus PS dialyzers was associated with equivalent dialysis adequacy, lower ESA doses, modestly lower Intravenous iron doses, and equivalent hemoglobin concentrations. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- ASAIO journal. Volume 62:Issue 5(2016)
- Journal:
- ASAIO journal
- Issue:
- Volume 62:Issue 5(2016)
- Issue Display:
- Volume 62, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 62
- Issue:
- 5
- Issue Sort Value:
- 2016-0062-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- dialysis -- dialyzer composition -- outcomes
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000409 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1671.xml