A New Approach for Decreasing the Detection Limit of Gentamicin Ion‐selective Electrodes by Incorporation of Multiwall Carbon Nanotubes (MWCNTs)/Lipophilic Anionic Additives. Issue 2 (14th September 2016)
- Record Type:
- Journal Article
- Title:
- A New Approach for Decreasing the Detection Limit of Gentamicin Ion‐selective Electrodes by Incorporation of Multiwall Carbon Nanotubes (MWCNTs)/Lipophilic Anionic Additives. Issue 2 (14th September 2016)
- Main Title:
- A New Approach for Decreasing the Detection Limit of Gentamicin Ion‐selective Electrodes by Incorporation of Multiwall Carbon Nanotubes (MWCNTs)/Lipophilic Anionic Additives
- Authors:
- Khalil, M. M.
El‐aziz, G. M. Abed - Abstract:
- Abstract: Two novel carbon paste electrodes based on gentamicin‐reineckate (GNS‐RN)/multiwall carbon nanotubes (MWCNTs)/sodium tetraphenyl borate (NaTPB) or potassium tetraphenylborate (KTPB) for potentiometric determination of gentamicin sulfate were constructed. Our endeavors of lowering the detection limit for gentamicin ion‐selective electrodes were described. The paper focused on gentamicin carbon paste electrodes based on GNS‐RN as electroactive material, o ‐nitrophenyloctyl ether ( o ‐NPOE) as plasticizer and incorporation of MWCNTs and lipophilic anionic additives (NaTPB and KTPB) which lower the detection limit of the electrodes showing best results for determination of gentamicin ion. The characteristics of the electrodes, GNS‐RN+NaTPB+MWCNTs (sensor 1) and GNS‐RN+KTPB+ MWCNTs (sensor 2), were measured, showing favorable features as they provided measurements of the potential with near‐Nernstian slopes of 29.6±0.3 and 29.1±0.3 mV/decade over the concentration range of 1.0×10 −6 –1.0×10 −2 mol L −1 and pH ranges 3.0–8.2 and 3.0–8.0 in short response times (6.5 sec). Importantly, the electrodes had low detection limits of 3.0×10 −7 and 3.4×10 −7 mol L −1 for the two sensors, respectively. The sensors showed high selectivity for gentamicin ion with respect to a large number of interfering species. The electrodes were successfully applied for the potentiometric determination of GNS ions in pure state, pharmaceutical preparations and human urine with high accuracy andAbstract: Two novel carbon paste electrodes based on gentamicin‐reineckate (GNS‐RN)/multiwall carbon nanotubes (MWCNTs)/sodium tetraphenyl borate (NaTPB) or potassium tetraphenylborate (KTPB) for potentiometric determination of gentamicin sulfate were constructed. Our endeavors of lowering the detection limit for gentamicin ion‐selective electrodes were described. The paper focused on gentamicin carbon paste electrodes based on GNS‐RN as electroactive material, o ‐nitrophenyloctyl ether ( o ‐NPOE) as plasticizer and incorporation of MWCNTs and lipophilic anionic additives (NaTPB and KTPB) which lower the detection limit of the electrodes showing best results for determination of gentamicin ion. The characteristics of the electrodes, GNS‐RN+NaTPB+MWCNTs (sensor 1) and GNS‐RN+KTPB+ MWCNTs (sensor 2), were measured, showing favorable features as they provided measurements of the potential with near‐Nernstian slopes of 29.6±0.3 and 29.1±0.3 mV/decade over the concentration range of 1.0×10 −6 –1.0×10 −2 mol L −1 and pH ranges 3.0–8.2 and 3.0–8.0 in short response times (6.5 sec). Importantly, the electrodes had low detection limits of 3.0×10 −7 and 3.4×10 −7 mol L −1 for the two sensors, respectively. The sensors showed high selectivity for gentamicin ion with respect to a large number of interfering species. The electrodes were successfully applied for the potentiometric determination of GNS ions in pure state, pharmaceutical preparations and human urine with high accuracy and precision. The results of this study were compared with some previously published data using other analytical methods. Abstract : … (more)
- Is Part Of:
- Electroanalysis. Volume 29:Issue 2(2017)
- Journal:
- Electroanalysis
- Issue:
- Volume 29:Issue 2(2017)
- Issue Display:
- Volume 29, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2017-0029-0002-0000
- Page Start:
- 566
- Page End:
- 577
- Publication Date:
- 2016-09-14
- Subjects:
- Ion-selective electrodes -- Gentamicin sulfate -- Multi-walled carbon nanotubes -- Lipophilic anionic additives -- Urine sample
Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.201600444 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 605.xml