Determination of the seismic performance factors for post‐tensioned rocking timber wall systems. (13th July 2016)
- Record Type:
- Journal Article
- Title:
- Determination of the seismic performance factors for post‐tensioned rocking timber wall systems. (13th July 2016)
- Main Title:
- Determination of the seismic performance factors for post‐tensioned rocking timber wall systems
- Authors:
- Sarti, Francesco
Palermo, Alessandro
Pampanin, Stefano
Berman, Jeffrey - Abstract:
- Summary: Post‐tensioned technologies for concrete seismic resistant buildings were first developed in the 1990s during the PREcast Seismic Structural Systems program. Among different solutions, the hybrid system proved to be the most resilient solution providing a combination of re‐centering and energy dissipative contributions respectively by using post‐tensioned tendons and mild steel reinforcement. The system, while providing significant strength and energy dissipation, reduces structural element damage and limits post‐earthquake residual displacements. More recently, the technology was extended to laminated veneer lumber (LVL) structural members, and extensive experimental and numerical work was carried out and allowed the development of reliable analytical and numerical models as well as design guidelines. On the basis of the experimental and numerical outcomes, this paper presents the evaluation of the seismic performance factors for post‐tensioned rocking LVL walls using the FEMA P‐695 procedure. Several archetype buildings were designed considering different parameters such as the building and story height, the type of seismic resistant system, the magnitude of gravity loads and the seismic design category. Lumped plasticity models were developed for each index archetype to simulate the behavioral aspects and collapse mechanisms. Non‐linear quasi‐static analyses were carried out to evaluate the system over‐strength factor; moreover, non‐linear time history analysesSummary: Post‐tensioned technologies for concrete seismic resistant buildings were first developed in the 1990s during the PREcast Seismic Structural Systems program. Among different solutions, the hybrid system proved to be the most resilient solution providing a combination of re‐centering and energy dissipative contributions respectively by using post‐tensioned tendons and mild steel reinforcement. The system, while providing significant strength and energy dissipation, reduces structural element damage and limits post‐earthquake residual displacements. More recently, the technology was extended to laminated veneer lumber (LVL) structural members, and extensive experimental and numerical work was carried out and allowed the development of reliable analytical and numerical models as well as design guidelines. On the basis of the experimental and numerical outcomes, this paper presents the evaluation of the seismic performance factors for post‐tensioned rocking LVL walls using the FEMA P‐695 procedure. Several archetype buildings were designed considering different parameters such as the building and story height, the type of seismic resistant system, the magnitude of gravity loads and the seismic design category. Lumped plasticity models were developed for each index archetype to simulate the behavioral aspects and collapse mechanisms. Non‐linear quasi‐static analyses were carried out to evaluate the system over‐strength factor; moreover, non‐linear time history analyses were performed using the incremental dynamic analysis concept to assess the collapse of each building. From the results of quasi‐static and dynamic analyses the response modification factor, R, system over‐strength factor, Ω0, and deflection amplification factor, Cd, values of, respectively, 7, 3.5 and 7.5 are recommended. Copyright © 2016 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Earthquake engineering and structural dynamics. Volume 46:Number 2(2017)
- Journal:
- Earthquake engineering and structural dynamics
- Issue:
- Volume 46:Number 2(2017)
- Issue Display:
- Volume 46, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 2
- Issue Sort Value:
- 2017-0046-0002-0000
- Page Start:
- 181
- Page End:
- 200
- Publication Date:
- 2016-07-13
- Subjects:
- post‐tensioned timber -- timber structures -- FEMA p‐695
Structural dynamics -- Periodicals
Earthquake engineering -- Periodicals
624.1762 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/eqe.2784 ↗
- Languages:
- English
- ISSNs:
- 0098-8847
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3643.575000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1634.xml