Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer. (March 2017)
- Record Type:
- Journal Article
- Title:
- Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer. (March 2017)
- Main Title:
- Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer
- Authors:
- Roth, Ralf
Donath, Lars
Kurz, Eduard
Zahner, Lukas
Faude, Oliver - Abstract:
- Abstract: Objectives: The present study aimed to assess the between day reliability of isokinetic and isometric peak torque (PT) during trunk measurement on an isokinetic device (IsoMed 2000). Design: Test-retest-protocol on five separate days. Participants: Fifteen healthy sport students (8 female and 7 male) aged 21 to 26. Main Outcome Measures: PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks. Results: For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85–0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% < CoV < 9.4%; 0.15 < SEM < 0.23) and isokinetic mode (60°/s: 3.7% < CoV < 8.6%; 0.08 < SEM < 0.24; 150°/s: 6.9% < CoV < 12.4%; 0.10 < SEM < 0.31). In contrast, reliability between familiarization day and day 1 was lower (6.6% < CoV < 26.2%; 0.10 < SEM < 0.65). Conclusions: Trunk strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied. Highlights: Isokinetic trunk strength measurement is highlyAbstract: Objectives: The present study aimed to assess the between day reliability of isokinetic and isometric peak torque (PT) during trunk measurement on an isokinetic device (IsoMed 2000). Design: Test-retest-protocol on five separate days. Participants: Fifteen healthy sport students (8 female and 7 male) aged 21 to 26. Main Outcome Measures: PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks. Results: For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85–0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% < CoV < 9.4%; 0.15 < SEM < 0.23) and isokinetic mode (60°/s: 3.7% < CoV < 8.6%; 0.08 < SEM < 0.24; 150°/s: 6.9% < CoV < 12.4%; 0.10 < SEM < 0.31). In contrast, reliability between familiarization day and day 1 was lower (6.6% < CoV < 26.2%; 0.10 < SEM < 0.65). Conclusions: Trunk strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied. Highlights: Isokinetic trunk strength measurement is highly reliable. A preceding familiarization condition should be applied. Strength changes due to interventions smaller than 10% seem to be detectable. … (more)
- Is Part Of:
- Physical therapy in sport. Volume 24(2017)
- Journal:
- Physical therapy in sport
- Issue:
- Volume 24(2017)
- Issue Display:
- Volume 24, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 24
- Issue:
- 2017
- Issue Sort Value:
- 2017-0024-2017-0000
- Page Start:
- 26
- Page End:
- 31
- Publication Date:
- 2017-03
- Subjects:
- Peak Torque -- Assessment -- Extension/Flexion -- Rotation
Sports physical therapy -- Periodicals
Sports injuries -- Patients -- Rehabilitation -- Periodicals
Athletic Injuries -- diagnosis -- Periodicals
Athletic Injuries -- therapy -- Periodicals
Physical Therapy -- Periodicals
Sports Medicine -- Periodicals
615.82088796 - Journal URLs:
- http://www.sciencedirect.com/science/journal/1466853X ↗
http://www.clinicalkey.com/dura/browse/journalIssue/1466853X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/1466853X ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journal ↗ - DOI:
- 10.1016/j.ptsp.2016.11.005 ↗
- Languages:
- English
- ISSNs:
- 1466-853X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6476.350650
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2634.xml