Determination of paroxetine in serum treated with simple pretreatment by pre‐column high‐performance liquid chromatography using 4‐(5, 6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride as a fluorescent labeling reagent. (14th January 2013)
- Record Type:
- Journal Article
- Title:
- Determination of paroxetine in serum treated with simple pretreatment by pre‐column high‐performance liquid chromatography using 4‐(5, 6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride as a fluorescent labeling reagent. (14th January 2013)
- Main Title:
- Determination of paroxetine in serum treated with simple pretreatment by pre‐column high‐performance liquid chromatography using 4‐(5, 6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride as a fluorescent labeling reagent
- Authors:
- Inoue, Hirofumi
Harada, Takuya
Eto, Seiji
Nakashima, Ken
Ibusuki, Takuya
Kosha, Keiko
Date, Yuuko
Sanematsu, Emiko
Shinohara, Yoshitake
Takahashi, Kojiro
Yoshimura, Reiji
Nakamura, Jun
Kojima, Eijiro
Tsuruta, Yasuto - Abstract:
- ABSTRACT: The therapeutic drug monitoring of paroxetine could be used to optimize the pharmacological treatment of depressed patients. A simple and sensitive high‐performance liquid chromatography procedure was developed for the determination of paroxetine in serum. After simple pretreatment of serum (50 μL) with acetonitrile and o ‐phthalaldehyde, paroxetine was derivatized with 4‐(5, 6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride at 70°C for 20 min in borate buffer (0.1 mol/L, pH 8.0) to produce a fluorescent product. The derivative was separated on a reversed‐phase column at 40°C for stepwise elution with (A) acetic acid (10 mmol/L) and (B) acetonitrile. The flow rate was 1.0 mL/min. The fluorescence intensity was monitored at excitation and emission wavelengths of 320 and 400 nm, respectively. The within‐day and day‐to‐day relative standard deviations were 3.0–3.4 and 2.7–8.3%, respectively. The detection limit of paroxetine was 8.3 fmol at a signal‐to‐noise ratio of 3. As the proposed method that only requires a small quantity of serum (50 μL) is simple, sensitive and reproducible, it would be useful for clinical and biochemical research as well as drug monitoring. Copyright © 2013 John Wiley & Sons, Ltd.
- Is Part Of:
- Biomedical chromatography. Volume 27:Number 6(2013:Jun.)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 27:Number 6(2013:Jun.)
- Issue Display:
- Volume 27, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 27
- Issue:
- 6
- Issue Sort Value:
- 2013-0027-0006-0000
- Page Start:
- 688
- Page End:
- 690
- Publication Date:
- 2013-01-14
- Subjects:
- paroxetine -- serum -- HPLC -- 4‐(5, 6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride -- fluorescence
Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.2859 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1521.xml