Immediate Loading of Fixed Complete Denture Prosthesis Supported by 4–8 Implants Placed Using Guided Surgery: A 5‐Year Prospective Study on 66 Patients with 356 Implants. (15th September 2016)
- Record Type:
- Journal Article
- Title:
- Immediate Loading of Fixed Complete Denture Prosthesis Supported by 4–8 Implants Placed Using Guided Surgery: A 5‐Year Prospective Study on 66 Patients with 356 Implants. (15th September 2016)
- Main Title:
- Immediate Loading of Fixed Complete Denture Prosthesis Supported by 4–8 Implants Placed Using Guided Surgery: A 5‐Year Prospective Study on 66 Patients with 356 Implants
- Authors:
- Meloni, Silvio Mario
Tallarico, Marco
Pisano, Milena
Xhanari, Erta
Canullo, Luigi - Abstract:
- Abstract: Background: High primary implant stability is considered one of the main factors necessary for achieving predictable treatment outcomes with immediately loaded implant‐supported screw‐retained fixed complete denture prosthesis (FCDP). Purpose: To evaluate the 5‐year clinical and radiographic outcomes of immediately loaded implants placed in edentulous patients using computer‐assisted template‐guided surgery to support a FCDP. Materials & Methods : Patients in need to be restored with a FCDP in the mandible or maxilla were included in this prospective study/ and treated using computer‐assisted template‐guided surgery. Implant sites were prepared in order to achieve an insertion torque ranging between 35–45 Ncm in the mandible and 45–55 Ncm in the maxilla. A prefabricated screw‐retained provisional prosthesis was delivered the day of the surgery. Outcomes were: implant and prosthesis cumulative survival rate (CSR), any complications, and peri‐implant marginal bone loss (MBL). Results: Sixty‐six patients received 356 implants to support 68 FCDPs. Each patient received 4–8 implants. Seven implants failed in six patients, resulting in a CSR of 98.1%. Two definitive prostheses failed resulting in CSR of 97.1%. Mean MBL of 1.62 ± 0.41 mm was reported at the 5‐year follow‐up. Five implants (1.4%) showed a mean mesio‐distal peri‐implant bone loss greater than 3.0 mm and received nonsurgical therapy. Conclusions: immediately loaded implants placed in edentulous patientsAbstract: Background: High primary implant stability is considered one of the main factors necessary for achieving predictable treatment outcomes with immediately loaded implant‐supported screw‐retained fixed complete denture prosthesis (FCDP). Purpose: To evaluate the 5‐year clinical and radiographic outcomes of immediately loaded implants placed in edentulous patients using computer‐assisted template‐guided surgery to support a FCDP. Materials & Methods : Patients in need to be restored with a FCDP in the mandible or maxilla were included in this prospective study/ and treated using computer‐assisted template‐guided surgery. Implant sites were prepared in order to achieve an insertion torque ranging between 35–45 Ncm in the mandible and 45–55 Ncm in the maxilla. A prefabricated screw‐retained provisional prosthesis was delivered the day of the surgery. Outcomes were: implant and prosthesis cumulative survival rate (CSR), any complications, and peri‐implant marginal bone loss (MBL). Results: Sixty‐six patients received 356 implants to support 68 FCDPs. Each patient received 4–8 implants. Seven implants failed in six patients, resulting in a CSR of 98.1%. Two definitive prostheses failed resulting in CSR of 97.1%. Mean MBL of 1.62 ± 0.41 mm was reported at the 5‐year follow‐up. Five implants (1.4%) showed a mean mesio‐distal peri‐implant bone loss greater than 3.0 mm and received nonsurgical therapy. Conclusions: immediately loaded implants placed in edentulous patients using computer‐assisted template‐guided surgery to support a FCDP is a valid treatment concept in the medium term follow‐up, for edentulous patients. … (more)
- Is Part Of:
- Clinical implant dentistry and related research. Volume 19:Number 1(2017:Feb.)
- Journal:
- Clinical implant dentistry and related research
- Issue:
- Volume 19:Number 1(2017:Feb.)
- Issue Display:
- Volume 19, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 19
- Issue:
- 1
- Issue Sort Value:
- 2017-0019-0001-0000
- Page Start:
- 195
- Page End:
- 206
- Publication Date:
- 2016-09-15
- Subjects:
- computer assisted surgery -- guided surgery -- immediate loading
Dental implants -- Periodicals
Dental Implantation -- Periodicals
Dental Implants -- Periodicals
617.693 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/cid.12449 ↗
- Languages:
- English
- ISSNs:
- 1523-0899
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293825
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 101.xml