Does Plasma ACE Level Accurately Reflect the Occurrence of Exercise‐Induced Pulmonary Haemorrhage?. (9th September 2013)
- Record Type:
- Journal Article
- Title:
- Does Plasma ACE Level Accurately Reflect the Occurrence of Exercise‐Induced Pulmonary Haemorrhage?. (9th September 2013)
- Main Title:
- Does Plasma ACE Level Accurately Reflect the Occurrence of Exercise‐Induced Pulmonary Haemorrhage?
- Authors:
- Richard, E.A.
Depecker, M.
Leleu, C.
Gennevieve, V.
Fortier, G.
Couroucé‐Malblanc, A.
Pitel, P.H. - Abstract:
- Abstract : Introduction: Exercise‐induced pulmonary haemorrhage (EIPH) is a highly prevalent airway disorder responsible for poor‐performance in horses. While various methodologies are available for diagnosing EIPH, no readily available systemic biomarker has to date been definitively validated. A recent study demonstrated that angiotensin‐converting enzyme (ACE) activity in plasma was increased in horses with higher degrees of haemorrhage, as assessed by post exercise tracheal endoscopy. Aims: To investigate plasma ACE activity in horses suffering previous episodes of EIPH and controls. Methods: Venous blood samples were collected at rest from 121 client‐owned, racing or race‐fit Standardbred racehorses. Bronchoalveolar lavage fluid (BALF) samples were collected from right and left lung, cytocentrifuged and stained with Perl's Prussian blue. Total haemosiderin scores (THS) were calculated for detecting EIPH. According to THS, 36 horses were diagnosed with EIPH and 85 were assigned as controls. The ACE levels were determined on an automated spectrophotometer, using FAPGG as a substrate. Results: Plasma ACE levels in EIPH‐affected horses (85.1 ± 24.6 u/l) were lower than those of control horses (94.4 ± 24.0 u/l), even if the tendency was not statistically significant (P = 0.056). Within each group of horse (EIPH and control), no significant difference was found for THS between lungs; a significant correlation between right and left BALF being furthermore observed (R = 0.643;Abstract : Introduction: Exercise‐induced pulmonary haemorrhage (EIPH) is a highly prevalent airway disorder responsible for poor‐performance in horses. While various methodologies are available for diagnosing EIPH, no readily available systemic biomarker has to date been definitively validated. A recent study demonstrated that angiotensin‐converting enzyme (ACE) activity in plasma was increased in horses with higher degrees of haemorrhage, as assessed by post exercise tracheal endoscopy. Aims: To investigate plasma ACE activity in horses suffering previous episodes of EIPH and controls. Methods: Venous blood samples were collected at rest from 121 client‐owned, racing or race‐fit Standardbred racehorses. Bronchoalveolar lavage fluid (BALF) samples were collected from right and left lung, cytocentrifuged and stained with Perl's Prussian blue. Total haemosiderin scores (THS) were calculated for detecting EIPH. According to THS, 36 horses were diagnosed with EIPH and 85 were assigned as controls. The ACE levels were determined on an automated spectrophotometer, using FAPGG as a substrate. Results: Plasma ACE levels in EIPH‐affected horses (85.1 ± 24.6 u/l) were lower than those of control horses (94.4 ± 24.0 u/l), even if the tendency was not statistically significant (P = 0.056). Within each group of horse (EIPH and control), no significant difference was found for THS between lungs; a significant correlation between right and left BALF being furthermore observed (R = 0.643; P<0.001). No significant correlation was however found between plasma ACE levels and THS of BALF from either left or right lung. Conclusions and practical significance: This is the first study determining plasma ACE activity in a large population of racehorses at training. Apart from acute pulmonary haemorrhage, these results highlight that previous episodes of EIPH might be associated with a moderate decrease of circulating ACE levels. Further studies are warranted to establish the precise implication of ACE in the physiopathology of EIPH and determine its relevance as a systemic biomarker. Ethical animal research: This study has been approved by the Regional Animal Ethic Committee and all owners gave consent.Sources of funding: I.F.C.E. (French National Studs) and S.E.C.F. (French Trotters Racing Association).Competing interests: None. … (more)
- Is Part Of:
- Equine veterinary journal. Volume 45(2013)Supplement 44
- Journal:
- Equine veterinary journal
- Issue:
- Volume 45(2013)Supplement 44
- Issue Display:
- Volume 45, Issue 44 (2013)
- Year:
- 2013
- Volume:
- 45
- Issue:
- 44
- Issue Sort Value:
- 2013-0045-0044-0000
- Page Start:
- 18
- Page End:
- 18
- Publication Date:
- 2013-09-09
- Subjects:
- Horses -- Diseases -- Periodicals
636.108905 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1001/(ISSN)2042-3306 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.ingentaconnect.com/content/evj/evj ↗ - DOI:
- 10.1111/evj.12145_44 ↗
- Languages:
- English
- ISSNs:
- 0425-1644
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3794.520000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1843.xml