Determination of critical breakage conditions for double glazing in fire. (25th January 2017)
- Record Type:
- Journal Article
- Title:
- Determination of critical breakage conditions for double glazing in fire. (25th January 2017)
- Main Title:
- Determination of critical breakage conditions for double glazing in fire
- Authors:
- Wang, Yu
Li, Ke
Su, Yanfei
Lu, Wei
Wang, Qingsong
Sun, Jinhua
He, Linghui
Liew, K.M. - Abstract:
- Highlights: Critical heat fluxes of exposed and ambient panes are 6 kW/m 2 and 25 kW/m 2 . Critical temperature difference of fire side pane is around 60 °C. The ambient pane survives three times longer due to radiation filter and air gap. Heat transfer in double glazing is revealed by a heat flux based theoretical model. Abstract: Double glazing unit normally demonstrates better fire resistance than single glazing, but the knowledge on its thermal behavior and heat transfer mechanism during fire is limited. In this work, nine double glazing units were heated by a 500 × 500 mm 2 pool fire. The incident heat flux, temperature on four surfaces, breakage time and cracking behavior were obtained. The critical breakage conditions for interior and exterior panes were determined through gradually decreasing the glass-burner distance from 750 mm to 450 mm. It is established that in double glazing the pane at ambient side can withstand significantly more time than the pane exposed to fire. The critical temperature difference for interior pane is 60 °C; the critical temperature of exterior pane breakage is much higher due to no frame-covered area. In addition, the heat flux at the time of crack initiation is 6 kW/m 2 for the pane at fire side, while more than 25 kW/m 2 for ambient side pane. To reveal the heat transfer mechanism in glazing-air-glazing, theoretical and numerical investigations are also performed, which agrees well with the experimental results.
- Is Part Of:
- Applied thermal engineering. Volume 111(2017:Jan.)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 111(2017:Jan.)
- Issue Display:
- Volume 111 (2017)
- Year:
- 2017
- Volume:
- 111
- Issue Sort Value:
- 2017-0111-0000-0000
- Page Start:
- 20
- Page End:
- 29
- Publication Date:
- 2017-01-25
- Subjects:
- Double glazing -- Thermal breakage -- Heat transfer -- Localized fire
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2016.09.079 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1600.xml