The approximated cardiovascular reserve index complies with haemorrhage related hemodynamic deterioration pattern: A swine exsanguination model. (February 2017)
- Record Type:
- Journal Article
- Title:
- The approximated cardiovascular reserve index complies with haemorrhage related hemodynamic deterioration pattern: A swine exsanguination model. (February 2017)
- Main Title:
- The approximated cardiovascular reserve index complies with haemorrhage related hemodynamic deterioration pattern: A swine exsanguination model
- Authors:
- Nadler, Roy
Glassberg, Elon
Gabbay, Itay E.
Wagnert-Avraham, Linn
Yaniv, Gal
Kushnir, David
Eisenkraft, Arik
Bobrovsky, Ben-Zion
Gabbay, Uri - Abstract:
- Abstract: Background: To estimate the cardiovascular reserve we formulated the Cardiovascular Reserve Index (CVRI) based on physiological measurements. The aim of this study was to evaluate the pattern of CVRI in haemorrhage-related haemodynamic deterioration in an animal model simulating combat injury. Methods: Data were collected retrospectively from a research database of swine exsanguination model in which serial physiological measurements were made under anesthesia in 12 swine of haemorrhagic injury and 5 controls. We calculated the approximated CVRI (CVRIA ). The course of haemodynamic deterioration was defined according to the cumulative blood loss until shock. The ability of heart rate (HR), mean arterial blood pressure (MABP), stroke volume (SV), cardiac output (CO) and systemic vascular resistance (SVR) and the CVRIA to predict haemodynamic deterioration was evaluated according to three criteria: strength of association with the course of haemodynamic deterioration (r 2 > 0.5); threshold for haemodynamic deterioration detection; and range at which the parameter remained consistently monotonous course of deterioration. Results: Three parameters met the first criterion for prediction of haemodynamic deterioration: HR (r 2 = 0.59), SV (r 2 = 0.57) and CVRIA (r 2 = 0.66). Results were negative for MABP (r 2 = 0.27), CO (r 2 = 0.33) and SVR (r 2 = 0.02). The detection threshold of the CVRIA was 200–300 ml blood loss whereas HR, SV and CO showed a delay inAbstract: Background: To estimate the cardiovascular reserve we formulated the Cardiovascular Reserve Index (CVRI) based on physiological measurements. The aim of this study was to evaluate the pattern of CVRI in haemorrhage-related haemodynamic deterioration in an animal model simulating combat injury. Methods: Data were collected retrospectively from a research database of swine exsanguination model in which serial physiological measurements were made under anesthesia in 12 swine of haemorrhagic injury and 5 controls. We calculated the approximated CVRI (CVRIA ). The course of haemodynamic deterioration was defined according to the cumulative blood loss until shock. The ability of heart rate (HR), mean arterial blood pressure (MABP), stroke volume (SV), cardiac output (CO) and systemic vascular resistance (SVR) and the CVRIA to predict haemodynamic deterioration was evaluated according to three criteria: strength of association with the course of haemodynamic deterioration (r 2 > 0.5); threshold for haemodynamic deterioration detection; and range at which the parameter remained consistently monotonous course of deterioration. Results: Three parameters met the first criterion for prediction of haemodynamic deterioration: HR (r 2 = 0.59), SV (r 2 = 0.57) and CVRIA (r 2 = 0.66). Results were negative for MABP (r 2 = 0.27), CO (r 2 = 0.33) and SVR (r 2 = 0.02). The detection threshold of the CVRIA was 200–300 ml blood loss whereas HR, SV and CO showed a delay in detection, MABP and CVRI exhibited a wide indicative range toward shock. Conclusions: The CVRIA met preset criteria of a potential predictor of haemorrhage-related haemodynamic deterioration. Prospective studies are required to evaluate use of the CVRI in combat medicine. Level of evidence: Level III. Highlights: Cardiovascular reserve index (CVRI) estimates the assumed cardiovascular reserve. CVRI is computed by routinely measured physiological parameters. Criteria for haemodynamic deterioration prediction were preset. CVRI met preset criteria (correlation, detecting threshold and indicative range). … (more)
- Is Part Of:
- Annals of medicine and surgery. Volume 14(2017)
- Journal:
- Annals of medicine and surgery
- Issue:
- Volume 14(2017)
- Issue Display:
- Volume 14, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 14
- Issue:
- 2017
- Issue Sort Value:
- 2017-0014-2017-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2017-02
- Subjects:
- Cardio-Vascular Reserve Index (CVRI) -- Haemodynamic deterioration -- Haemorrhage -- Shock -- Swine model
Surgery -- Periodicals
Medicine -- Periodicals
General Surgery -- Periodicals
Education, Medical -- Periodicals
Periodicals
617 - Journal URLs:
- http://www.sciencedirect.com/science/journal/20490801 ↗
http://bibpurl.oclc.org/web/73795 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/20490801 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/20490801 ↗
http://www.annalsjournal.com/home ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.amsu.2016.12.052 ↗
- Languages:
- English
- ISSNs:
- 2049-0801
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1750.xml