Direct quantitative analysis of cocaine by thin layer chromatography plus a mobile phone and multivariate calibration: a cost-effective and rapid method. Issue 42 (12th October 2016)
- Record Type:
- Journal Article
- Title:
- Direct quantitative analysis of cocaine by thin layer chromatography plus a mobile phone and multivariate calibration: a cost-effective and rapid method. Issue 42 (12th October 2016)
- Main Title:
- Direct quantitative analysis of cocaine by thin layer chromatography plus a mobile phone and multivariate calibration: a cost-effective and rapid method
- Authors:
- Tosato, Flávia
Rosa, Thalles R.
Morais, Camilo L. M.
Maldaner, Adriano O.
Ortiz, Rafael S.
Filgueiras, Paulo R.
Gomes Lima, Kássio M.
Romão, Wanderson - Abstract:
- Abstract : The detection and quantification of trace amounts of illicit substances such as crack-cocaine continues to be important for law enforcement and clinical medicine. Abstract : The detection and quantification of trace amounts of illicit substances such as crack-cocaine continues to be important for law enforcement and clinical medicine. Conventional methods available for crack-cocaine and adulterant detection include chromatography and presumptive testing. Here, we report a simple and inexpensive approach that employs a cell phone which images of thin-layer chromatography (TLC) plates were acquired to directly quantify cocaine and phenacetin in illicit samples seized in Brazil from 2012. Integration of a mobile application with a cell phone enabled immediate processing of TLC results, which eliminated the need for a bulky and expensive spectrometer. Partial least squares (PLS) regression was built using the RGB image system from the TLC plates containing cocaine (0.50 to 16.00 mg mL −1 ) and phenacetin (0.00 to 14.00 mg mL −1 ) as adulterants, acquired from a cell phone camera. The RMSEP values obtained for cocaine and phenacetin models were, respectively, equal to 1.60 and 1.36 mg mL −1, and their precision was respectively equal to 6.22 and 7.14%. No statistical difference was observed at a confidence level of 95% for both analytes calculated by the proposed method and those found by the reference method using gas chromatography with flame ionization detectionAbstract : The detection and quantification of trace amounts of illicit substances such as crack-cocaine continues to be important for law enforcement and clinical medicine. Abstract : The detection and quantification of trace amounts of illicit substances such as crack-cocaine continues to be important for law enforcement and clinical medicine. Conventional methods available for crack-cocaine and adulterant detection include chromatography and presumptive testing. Here, we report a simple and inexpensive approach that employs a cell phone which images of thin-layer chromatography (TLC) plates were acquired to directly quantify cocaine and phenacetin in illicit samples seized in Brazil from 2012. Integration of a mobile application with a cell phone enabled immediate processing of TLC results, which eliminated the need for a bulky and expensive spectrometer. Partial least squares (PLS) regression was built using the RGB image system from the TLC plates containing cocaine (0.50 to 16.00 mg mL −1 ) and phenacetin (0.00 to 14.00 mg mL −1 ) as adulterants, acquired from a cell phone camera. The RMSEP values obtained for cocaine and phenacetin models were, respectively, equal to 1.60 and 1.36 mg mL −1, and their precision was respectively equal to 6.22 and 7.14%. No statistical difference was observed at a confidence level of 95% for both analytes calculated by the proposed method and those found by the reference method using gas chromatography with flame ionization detection (GC-FID), proving the reliability of the imaging method as an alternative approach for these assays. … (more)
- Is Part Of:
- Analytical methods. Volume 8:Issue 42(2016)
- Journal:
- Analytical methods
- Issue:
- Volume 8:Issue 42(2016)
- Issue Display:
- Volume 8, Issue 42 (2017)
- Year:
- 2017
- Volume:
- 8
- Issue:
- 42
- Issue Sort Value:
- 2017-0008-0042-0000
- Page Start:
- 7632
- Page End:
- 7637
- Publication Date:
- 2016-10-12
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ay02126c ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2734.xml