Comparison of positive pressure ventilation devices in a newborn manikin. (4th March 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of positive pressure ventilation devices in a newborn manikin. (4th March 2017)
- Main Title:
- Comparison of positive pressure ventilation devices in a newborn manikin
- Authors:
- Solevåg, Anne Lee
Haemmerle, Enrico
van Os, Sylvia
Bach, Katinka P.
Cheung, Po-Yin
Schmölzer, Georg M. - Abstract:
- Abstract: Objective : To compare tidal volume (VT ) delivery and ventilation rate between devices for positive pressure ventilation (PPV) during newborn resuscitation. Methods : Neonatal resuscitation program providers ( n = 25) delivered PPV to a newborn manikin in a randomized order with: a self-inflating bag (SIB), a disposable T-piece, a non-disposable T-piece, a stand-alone infant resuscitation system T-piece and the volume-controlled prototype Next Step TM device (KM Medical). All T-pieces used a peak inflation pressure of 20cmH2 O and a 5cmH2 O positive end-expiratory pressure (PEEP). The SIB neither had a PEEP valve nor manometer. The Next Step TM had a 5cmH2 O PEEP valve. The participants aimed to deliver a 5 mL/kg VT (rate 40–60 min − 1 ) for 1 min with each device and each of three compliances (0.5, 1.0 and 2.0 mL/cmH2 O). VT and ventilation rate were compared between devices and compliance levels (ANOVA) Results : All devices, except the Next Step TM delivered a 4–5 mL/kg VT at the low compliance, but three- to four-fold that of the target at the higher compliance levels. The Next Step TM delivered a VT close to target at all compliance levels. The ventilation rate was within 40–60 min − 1 with all devices and compliance levels. Conclusions : Routinely used ventilation devices for newborn resuscitation can triple intended VT and requires further investigation.
- Is Part Of:
- Journal of maternal-fetal & neonatal medicine. Volume 30:Number 5(2017)
- Journal:
- Journal of maternal-fetal & neonatal medicine
- Issue:
- Volume 30:Number 5(2017)
- Issue Display:
- Volume 30, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2017-0030-0005-0000
- Page Start:
- 595
- Page End:
- 599
- Publication Date:
- 2017-03-04
- Subjects:
- Resuscitation -- tidal volume -- ventilation rate
Obstetrics -- Periodicals
Perinatology -- Periodicals
Infants (Newborn) -- Diseases -- Periodicals
Neonatology -- Periodicals
618.2 - Journal URLs:
- http://informahealthcare.com/loi/jmf ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/14767058.2016.1180360 ↗
- Languages:
- English
- ISSNs:
- 1476-7058
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.332000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1166.xml