Dual‐Pathway sequences for MR thermometry: When and where to use them. Issue 3 (10th March 2016)
- Record Type:
- Journal Article
- Title:
- Dual‐Pathway sequences for MR thermometry: When and where to use them. Issue 3 (10th March 2016)
- Main Title:
- Dual‐Pathway sequences for MR thermometry: When and where to use them
- Authors:
- Ciris, Pelin Aksit
Cheng, Cheng‐Chieh
Mei, Chang‐Sheng
Panych, Lawrence P.
Madore, Bruno - Abstract:
- Abstract : Purpose: Dual‐pathway sequences have been proposed to help improve the temperature‐to‐noise ratio (TNR) in MR thermometry. The present work establishes how much of an improvement these so‐called "PSIF‐FISP" sequences may bring in various organs and tissues. Methods: Simulations and TNR calculations were validated against analytical equations, phantom, abdomen, and brain scans. Relative TNRs for PSIF‐FISP, as compared to a dual‐FISP reference standard, were calculated for flip angle (FA) = 1 to 85 º and repetition time (TR) = 6 to 60 ms, for gray matter, white matter, cervix, endometrium, myometrium, prostate, kidney medulla and cortex, bone marrow, pancreas, spleen, muscle, and liver tissues. Results: PSIF‐FISP was TNR superior in the kidney, pelvis, spleen, or gray matter at most tested TR and FA settings, and benefits increased at shorter TRs. PSIF‐FISP was TNR superior in other tissues, e.g., liver, muscle, pancreas, for only short TR settings (20 ms or less). The TNR benefits of PSIF‐FISP increased slightly with FA, and strongly with decreasing TR. Up to two‐ to three‐fold reductions in TR with 20% TNR gains were achievable. In any given tissue, TNR performance is expected to further improve with heating, due to changes in relaxation rates. Conclusion: Dual‐pathway PSIF‐FISP can improve TNR and acquisition speed over standard gradient‐recalled echo sequences, but optimal acquisition parameters are tissue dependent. Magn Reson Med 77:1193–1200, 2017. © 2016Abstract : Purpose: Dual‐pathway sequences have been proposed to help improve the temperature‐to‐noise ratio (TNR) in MR thermometry. The present work establishes how much of an improvement these so‐called "PSIF‐FISP" sequences may bring in various organs and tissues. Methods: Simulations and TNR calculations were validated against analytical equations, phantom, abdomen, and brain scans. Relative TNRs for PSIF‐FISP, as compared to a dual‐FISP reference standard, were calculated for flip angle (FA) = 1 to 85 º and repetition time (TR) = 6 to 60 ms, for gray matter, white matter, cervix, endometrium, myometrium, prostate, kidney medulla and cortex, bone marrow, pancreas, spleen, muscle, and liver tissues. Results: PSIF‐FISP was TNR superior in the kidney, pelvis, spleen, or gray matter at most tested TR and FA settings, and benefits increased at shorter TRs. PSIF‐FISP was TNR superior in other tissues, e.g., liver, muscle, pancreas, for only short TR settings (20 ms or less). The TNR benefits of PSIF‐FISP increased slightly with FA, and strongly with decreasing TR. Up to two‐ to three‐fold reductions in TR with 20% TNR gains were achievable. In any given tissue, TNR performance is expected to further improve with heating, due to changes in relaxation rates. Conclusion: Dual‐pathway PSIF‐FISP can improve TNR and acquisition speed over standard gradient‐recalled echo sequences, but optimal acquisition parameters are tissue dependent. Magn Reson Med 77:1193–1200, 2017. © 2016 International Society for Magnetic Resonance in Medicine … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 3(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 3(2017)
- Issue Display:
- Volume 77, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 3
- Issue Sort Value:
- 2017-0077-0003-0000
- Page Start:
- 1193
- Page End:
- 1200
- Publication Date:
- 2016-03-10
- Subjects:
- MR thermometry -- multipathway sequences -- temperature‐to‐noise ratio -- PSIF -- DESS -- proton resonance frequency shift
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26177 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1871.xml