Comparison of T2, T1rho, and diffusion metrics in assessment of liver fibrosis in rats. Issue 3 (16th August 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of T2, T1rho, and diffusion metrics in assessment of liver fibrosis in rats. Issue 3 (16th August 2016)
- Main Title:
- Comparison of T2, T1rho, and diffusion metrics in assessment of liver fibrosis in rats
- Authors:
- Zhang, Hui
Yang, Qihua
Yu, Taihui
Chen, Xiaodong
Huang, Jingwen
Tan, Cui
Liang, Biling
Guo, Hua - Abstract:
- Abstract : Purpose: To evaluate the value of T 2, T 1 rho, and diffusion metrics in assessment of liver fibrosis in rats. Materials and Methods: Liver fibrosis in a rat model ( n = 72) was induced by injection of carbon tetrachloride (CCl4 ) at 3T. T 2, T 1 rho, and diffusion parameters (apparent diffusion coefficient (ADC), Dtrue ) via spin echo (SE) diffusion‐weighted imaging (DWI) and stimulated echo acquisition mode (STEAM) DWI with three diffusion times (DT: 80, 106, 186 msec) were obtained in surviving rats with hepatic fibrosis ( n = 52) and controls ( n = 8). Liver fibrosis stage (F0–F6) was identified based on pathological results using the traditional liver fibrosis staging method for rodents. Nonparametric statistical methods and receiver operating characteristic (ROC) curve analysis were employed to determine the diagnostic accuracy. Results: Mean T 2, T 1 rho, ADC, and Dtrue with DT = 186 msec correlated with the severity of fibrosis with r = 0.73, 0.83, −0.83, and −0.85 (all P < 0.001), respectively. The average areas under the ROC curve at different stages for T 1 rho and diffusion parameters (DT = 186 msec) were larger than those of T 2 and SE DWI (0.92, 0.92, and 0.92 vs. 0.86, 0.82, and 0.83). The corresponding average sensitivity and specificity for T 1 rho and diffusion parameters with a long DT were larger (89.35 and 88.90, 88.36 and 89.97, 90.16 and 87.13) than T 2 and SE DWI (90.28 and 79.93, 85.30 and 77.64, 78.21 and 82.41). The performances of TAbstract : Purpose: To evaluate the value of T 2, T 1 rho, and diffusion metrics in assessment of liver fibrosis in rats. Materials and Methods: Liver fibrosis in a rat model ( n = 72) was induced by injection of carbon tetrachloride (CCl4 ) at 3T. T 2, T 1 rho, and diffusion parameters (apparent diffusion coefficient (ADC), Dtrue ) via spin echo (SE) diffusion‐weighted imaging (DWI) and stimulated echo acquisition mode (STEAM) DWI with three diffusion times (DT: 80, 106, 186 msec) were obtained in surviving rats with hepatic fibrosis ( n = 52) and controls ( n = 8). Liver fibrosis stage (F0–F6) was identified based on pathological results using the traditional liver fibrosis staging method for rodents. Nonparametric statistical methods and receiver operating characteristic (ROC) curve analysis were employed to determine the diagnostic accuracy. Results: Mean T 2, T 1 rho, ADC, and Dtrue with DT = 186 msec correlated with the severity of fibrosis with r = 0.73, 0.83, −0.83, and −0.85 (all P < 0.001), respectively. The average areas under the ROC curve at different stages for T 1 rho and diffusion parameters (DT = 186 msec) were larger than those of T 2 and SE DWI (0.92, 0.92, and 0.92 vs. 0.86, 0.82, and 0.83). The corresponding average sensitivity and specificity for T 1 rho and diffusion parameters with a long DT were larger (89.35 and 88.90, 88.36 and 89.97, 90.16 and 87.13) than T 2 and SE DWI (90.28 and 79.93, 85.30 and 77.64, 78.21 and 82.41). The performances of T 1 rho and Dtrue (DT = 186 msec) were comparable (average AUC: 0.92 and 0.92). Conclusion: Among the evaluated sequences, T 1 rho and STEAM DWI with a long DT may serve as superior imaging biomarkers for assessing liver fibrosis and monitoring disease severity. Level of Evidence: 1 J. Magn. Reson. Imaging 2017;45:741–750. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 45:Issue 3(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 45:Issue 3(2017)
- Issue Display:
- Volume 45, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 3
- Issue Sort Value:
- 2017-0045-0003-0000
- Page Start:
- 741
- Page End:
- 750
- Publication Date:
- 2016-08-16
- Subjects:
- liver fibrosis -- fibrosis staging -- diffusion time -- T1rho mapping -- T2 mapping -- STEAM DWI
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25424 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 595.xml