Feasibility of using low-cost portable particle monitors for measurement of fine and coarse particulate matter in urban ambient air. (4th March 2017)
- Record Type:
- Journal Article
- Title:
- Feasibility of using low-cost portable particle monitors for measurement of fine and coarse particulate matter in urban ambient air. (4th March 2017)
- Main Title:
- Feasibility of using low-cost portable particle monitors for measurement of fine and coarse particulate matter in urban ambient air
- Authors:
- Han, Inkyu
Symanski, Elaine
Stock, Thomas H. - Abstract:
- ABSTRACT: Exposure to ambient particulate matter (PM) is known as a significant risk factor for mortality and morbidity due to cardiorespiratory causes. Owing to increased interest in assessing personal and community exposures to PM, we evaluated the feasibility of employing a low-cost portable direct-reading instrument for measurement of ambient air PM exposure. A Dylos DC 1700 PM sensor was collocated with a Grimm 11-R in an urban residential area of Houston Texas. The 1-min averages of particle number concentrations for sizes between 0.5 and 2.5 µm (small size) and sizes larger than 2.5 µm (large size) from a DC 1700 were compared with the 1-min averages of PM2.5 (aerodynamic size less than 2.5 µm) and coarse PM (aerodynamic size between 2.5 and 10 µm) concentrations from a Grimm 11-R. We used a linear regression equation to convert DC 1700 number concentrations to mass concentrations, utilizing measurements from the Grimm 11-R. The estimated average DC 1700 PM2.5 concentration (13.2 ± 13.7 µg/m 3 ) was similar to the average measured Grimm 11-R PM2.5 concentration (11.3 ± 15.1 µg/m 3 ). The overall correlation ( r 2 ) for PM2.5 between the DC 1700 and Grimm 11-R was 0.778. The estimated average coarse PM concentration from the DC 1700 (5.6 ± 12.1 µg/m 3 ) was also similar to that measured with the Grimm 11-R (4.8 ± 16.5 µg/m 3 ) with an r 2 of 0.481. The effects of relative humidity and particle size on the association between the DC 1700 and the Grimm 11-R results wereABSTRACT: Exposure to ambient particulate matter (PM) is known as a significant risk factor for mortality and morbidity due to cardiorespiratory causes. Owing to increased interest in assessing personal and community exposures to PM, we evaluated the feasibility of employing a low-cost portable direct-reading instrument for measurement of ambient air PM exposure. A Dylos DC 1700 PM sensor was collocated with a Grimm 11-R in an urban residential area of Houston Texas. The 1-min averages of particle number concentrations for sizes between 0.5 and 2.5 µm (small size) and sizes larger than 2.5 µm (large size) from a DC 1700 were compared with the 1-min averages of PM2.5 (aerodynamic size less than 2.5 µm) and coarse PM (aerodynamic size between 2.5 and 10 µm) concentrations from a Grimm 11-R. We used a linear regression equation to convert DC 1700 number concentrations to mass concentrations, utilizing measurements from the Grimm 11-R. The estimated average DC 1700 PM2.5 concentration (13.2 ± 13.7 µg/m 3 ) was similar to the average measured Grimm 11-R PM2.5 concentration (11.3 ± 15.1 µg/m 3 ). The overall correlation ( r 2 ) for PM2.5 between the DC 1700 and Grimm 11-R was 0.778. The estimated average coarse PM concentration from the DC 1700 (5.6 ± 12.1 µg/m 3 ) was also similar to that measured with the Grimm 11-R (4.8 ± 16.5 µg/m 3 ) with an r 2 of 0.481. The effects of relative humidity and particle size on the association between the DC 1700 and the Grimm 11-R results were also examined. The calculated PM mass concentrations from the DC 1700 were close to those measured with the Grimm 11-R when relative humidity was less than 60% for both PM2.5 and coarse PM. Particle size distribution was more important for the association of coarse PM between the DC 1700 and Grimm 11-R than it was for PM2.5 . Implications : The performance of a low-cost particulate matter (PM) sensor was evaluated in an urban residential area. Both PM2.5 and coarse PM (PM10-2.5 ) mass concentrations were estimated using a DC1700 PM sensor. The calculated PM mass concentrations from the number concentrations of DC 1700 were close to those measured with the Grimm 11-R when relative humidity was less than 60% for both PM2.5 and coarse PM. Particle size distribution was more important for the association of coarse PM between the DC 1700 and Grimm 11-R than it was for PM2.5 . … (more)
- Is Part Of:
- Journal of the Air & Waste Management Association. Volume 67:Number 3(2017)
- Journal:
- Journal of the Air & Waste Management Association
- Issue:
- Volume 67:Number 3(2017)
- Issue Display:
- Volume 67, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 67
- Issue:
- 3
- Issue Sort Value:
- 2017-0067-0003-0000
- Page Start:
- 330
- Page End:
- 340
- Publication Date:
- 2017-03-04
- Subjects:
- Air -- Pollution -- Periodicals
Air quality management -- Periodicals
Hazardous wastes -- Management -- Periodicals
Air Pollution -- prevention & control -- Periodicals
Hazardous Waste -- prevention & control -- Periodicals
Waste Management -- Periodicals
628.5305 - Journal URLs:
- http://secure.awma.org/journal/Archives.aspx ↗
http://vnweb.hwwilsonweb.com/hww/Journals/searchAction.jhtml?sid=HWW:ASTFT&issn=1096-2247 ↗
http://www.tandfonline.com/loi/uawm20 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10962247.2016.1241195 ↗
- Languages:
- English
- ISSNs:
- 1047-3289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4682.450000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2621.xml