Acute Slow Wave Responses to High‐Frequency Gastric Electrical Stimulation in Patients With Gastroparesis Defined by High‐Resolution Mapping. Issue 8 (10th June 2016)
- Record Type:
- Journal Article
- Title:
- Acute Slow Wave Responses to High‐Frequency Gastric Electrical Stimulation in Patients With Gastroparesis Defined by High‐Resolution Mapping. Issue 8 (10th June 2016)
- Main Title:
- Acute Slow Wave Responses to High‐Frequency Gastric Electrical Stimulation in Patients With Gastroparesis Defined by High‐Resolution Mapping
- Authors:
- Angeli, Timothy R.
Du, Peng
Midgley, David
Paskaranandavadivel, Niranchan
Sathar, Shameer
Lahr, Christopher
Abell, Thomas L.
Cheng, Leo K.
O'Grady, Gregory - Abstract:
- Abstract : Background and Aims: High‐frequency gastric electrical stimulation (GES) has emerged as a therapy for gastroparesis, but the mechanism(s) of action remain unclear. There is a need to refine stimulation protocols for clinical benefit, but a lack of accurate techniques for assessing mechanisms in clinical trials, such as slow wave modulation, has hindered progress. We thereby aimed to assess acute slow wave responses to GES in gastroparesis patients using high‐resolution (HR) (multi‐electrode) mapping, across a range of stimulation doses achievable by the Enterra stimulation device (Medtronic Inc., MN, USA). Materials and Methods: Patients with medically refractory gastroparesis ( n = 8) undergoing device implantation underwent intraoperative HR mapping (256 electrodes). Baseline recordings were followed by four protocols of increasing stimulation intensity, with washout periods. Slow wave patterns, frequency, velocity, amplitude, and dysrhythmia rates were quantified by investigators blinded to stimulation settings. Results: There was no difference in slow wave pattern, frequency, velocity, or amplitude between baseline, washout, and stimulation periods (all p > 0.5). Dysrhythmias included ectopic pacemakers, conduction blocks, retrograde propagation, and colliding wavefronts, and dysrhythmia rates were unchanged with stimulation off vs. on (31% vs. 36% duration dysrhythmic; p > 0.5). Symptom scores and gastric emptying were improved at 5.8 month follow‐up ( pAbstract : Background and Aims: High‐frequency gastric electrical stimulation (GES) has emerged as a therapy for gastroparesis, but the mechanism(s) of action remain unclear. There is a need to refine stimulation protocols for clinical benefit, but a lack of accurate techniques for assessing mechanisms in clinical trials, such as slow wave modulation, has hindered progress. We thereby aimed to assess acute slow wave responses to GES in gastroparesis patients using high‐resolution (HR) (multi‐electrode) mapping, across a range of stimulation doses achievable by the Enterra stimulation device (Medtronic Inc., MN, USA). Materials and Methods: Patients with medically refractory gastroparesis ( n = 8) undergoing device implantation underwent intraoperative HR mapping (256 electrodes). Baseline recordings were followed by four protocols of increasing stimulation intensity, with washout periods. Slow wave patterns, frequency, velocity, amplitude, and dysrhythmia rates were quantified by investigators blinded to stimulation settings. Results: There was no difference in slow wave pattern, frequency, velocity, or amplitude between baseline, washout, and stimulation periods (all p > 0.5). Dysrhythmias included ectopic pacemakers, conduction blocks, retrograde propagation, and colliding wavefronts, and dysrhythmia rates were unchanged with stimulation off vs. on (31% vs. 36% duration dysrhythmic; p > 0.5). Symptom scores and gastric emptying were improved at 5.8 month follow‐up ( p < 0.05). Conclusions: High‐frequency GES protocols achievable from a current commercial device did not acutely modulate slow wave activity or dysrhythmias. This study advances clinical methods for identifying and assessing therapeutic GES parameters, and can be applied in future studies on higher‐energy protocols and devices. … (more)
- Is Part Of:
- Neuromodulaton. Volume 19:Issue 8(2016)
- Journal:
- Neuromodulaton
- Issue:
- Volume 19:Issue 8(2016)
- Issue Display:
- Volume 19, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 19
- Issue:
- 8
- Issue Sort Value:
- 2016-0019-0008-0000
- Page Start:
- 864
- Page End:
- 871
- Publication Date:
- 2016-06-10
- Subjects:
- Diabetes mellitus -- electrophysiology -- high‐resolution mapping -- pacing -- slow wave
Central nervous system -- Physiology -- Periodicals
Central nervous system -- Diseases -- Periodicals
616.8 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1403 ↗
https://www.sciencedirect.com/journal/neuromodulation-technology-at-the-neural-interface ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ner.12454 ↗
- Languages:
- English
- ISSNs:
- 1094-7159
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.504100
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 58.xml