Device-related pressure ulcers from a biomechanical perspective. Issue 1 (February 2017)
- Record Type:
- Journal Article
- Title:
- Device-related pressure ulcers from a biomechanical perspective. Issue 1 (February 2017)
- Main Title:
- Device-related pressure ulcers from a biomechanical perspective
- Authors:
- Levy, Ayelet
Kopplin, Kara
Gefen, Amit - Abstract:
- Abstract: Pressure ulcers (PUs) in the pediatric population are inherently different from those in adults, in their risk factors and etiology, with more than 50% of the cases related to contact with medical equipment at the care setting. The aims of this study were to: (i) Determine the mechanical loads in the scalp of a newborn lying supine, near a wedged encephalogram electrode or wire, which is deforming the scalp at the occiput. (ii) Evaluate the effect of a doughnut-shaped headrest on the mechanical state of tissues at the same site. We used finite element computational modeling to simulate a realistic three-dimensional head of a newborn interacting with the above devices. We examined effective (von Mises) stresses, shear stresses and strain energy density (SED) in the fat and skin tissues at the occipital region. The interfering wire resulted in the worse mechanical conditions in the soft tissues, compared to the lodged electrode and use of a doughnut-shaped headrest, with 345% and 50% increase in effective stresses in skin and fat tissues, respectively. Considering that elevated and localized tissue deformations, stresses and SED indicate a risk for PUs, our simulations suggest that misplaced medical devices, and using a doughnut-shaped headrest, impose an actual risk for developing device-related PUs. We conclude that guidelines for pediatric clinical care should recommend routine inspection of the medical device placement to prevent harmful contact conditions withAbstract: Pressure ulcers (PUs) in the pediatric population are inherently different from those in adults, in their risk factors and etiology, with more than 50% of the cases related to contact with medical equipment at the care setting. The aims of this study were to: (i) Determine the mechanical loads in the scalp of a newborn lying supine, near a wedged encephalogram electrode or wire, which is deforming the scalp at the occiput. (ii) Evaluate the effect of a doughnut-shaped headrest on the mechanical state of tissues at the same site. We used finite element computational modeling to simulate a realistic three-dimensional head of a newborn interacting with the above devices. We examined effective (von Mises) stresses, shear stresses and strain energy density (SED) in the fat and skin tissues at the occipital region. The interfering wire resulted in the worse mechanical conditions in the soft tissues, compared to the lodged electrode and use of a doughnut-shaped headrest, with 345% and 50% increase in effective stresses in skin and fat tissues, respectively. Considering that elevated and localized tissue deformations, stresses and SED indicate a risk for PUs, our simulations suggest that misplaced medical devices, and using a doughnut-shaped headrest, impose an actual risk for developing device-related PUs. We conclude that guidelines for pediatric clinical care should recommend routine inspection of the medical device placement to prevent harmful contact conditions with the patient. Furthermore, improved design of medical equipment for pediatric settings is needed in order to protect these fragile young patients from PUs. … (more)
- Is Part Of:
- Journal of tissue viability. Volume 26:Issue 1(2017:Feb.)
- Journal:
- Journal of tissue viability
- Issue:
- Volume 26:Issue 1(2017:Feb.)
- Issue Display:
- Volume 26, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 26
- Issue:
- 1
- Issue Sort Value:
- 2017-0026-0001-0000
- Page Start:
- 57
- Page End:
- 68
- Publication Date:
- 2017-02
- Subjects:
- Pediatric pressure ulcers -- Computer simulations -- Medical devices
Wounds and injuries -- Periodicals
Ulcers -- Periodicals
Bedsores -- Periodicals
Bedsores
Ulcers
Wounds and injuries
Electronic journals
Periodicals
617.1406 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0965206X ↗
http://www.sciencedirect.com/science/journal/02680009 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jtv.2016.02.002 ↗
- Languages:
- English
- ISSNs:
- 0965-206X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.540000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2060.xml