Characteristics of the most intense lightning storm ever recorded at the CN Tower. (February 2017)
- Record Type:
- Journal Article
- Title:
- Characteristics of the most intense lightning storm ever recorded at the CN Tower. (February 2017)
- Main Title:
- Characteristics of the most intense lightning storm ever recorded at the CN Tower
- Authors:
- Hussein, A.M.
Kazazi, S.
Anwar, M.
Yusouf, M.
Liatos, P. - Abstract:
- Abstract: Lightning strikes to the CN Tower have been optically observed since 1978. In 1990, five independent systems started to operate to simultaneously record parameters of lightning strikes to the tower, including the time derivative of the current, the associated electric and magnetic fields, and the channel optical characteristics. On August 24, 2011, during an unusually severe lightning storm, video records showed that the CN Tower was struck with 52 lightning flashes within 84 min and 6.9 s. Thus, this storm produced, on average, a flash to the tower every 99 s. However, the CN Tower lightning current derivative measurement system only recorded 32 flashes, which were perfectly time-matched with 32 of the 52 video-recorded flashes. It is found that the current derivative measurement system recorded every video-recorded flash that contained at least one return stroke. Based on the analysis of video records, it is noted that each of the storm's 52 flashes contains an initial-stage current, proving that all flashes were upward initiated. This unique CN Tower storm – the most intense ever recorded at the tower – is here thoroughly analyzed, based on video and current records. The inter-flash time within the storm is found to vary between 10.6 s and 274 s, with an overall average of 98 s. It is also found that the inter-flash time between successive non-return-stroke flashes is on average 64% longer than that for successive flashes containing return strokes. StatisticalAbstract: Lightning strikes to the CN Tower have been optically observed since 1978. In 1990, five independent systems started to operate to simultaneously record parameters of lightning strikes to the tower, including the time derivative of the current, the associated electric and magnetic fields, and the channel optical characteristics. On August 24, 2011, during an unusually severe lightning storm, video records showed that the CN Tower was struck with 52 lightning flashes within 84 min and 6.9 s. Thus, this storm produced, on average, a flash to the tower every 99 s. However, the CN Tower lightning current derivative measurement system only recorded 32 flashes, which were perfectly time-matched with 32 of the 52 video-recorded flashes. It is found that the current derivative measurement system recorded every video-recorded flash that contained at least one return stroke. Based on the analysis of video records, it is noted that each of the storm's 52 flashes contains an initial-stage current, proving that all flashes were upward initiated. This unique CN Tower storm – the most intense ever recorded at the tower – is here thoroughly analyzed, based on video and current records. The inter-flash time within the storm is found to vary between 10.6 s and 274 s, with an overall average of 98 s. It is also found that the inter-flash time between successive non-return-stroke flashes is on average 64% longer than that for successive flashes containing return strokes. Statistical analysis of video and current data clearly reveals that the time duration of flashes containing initial-stage currents and return strokes is on average 27% longer than that of flashes that only have initial-stage currents. Furthermore, it is important to note that the time duration of the initial-stage current in flashes containing no return strokes is on average 76% longer than that in flashes containing return strokes. Therefore, it is possible to conclude that if the time duration of the initial-stage current in a flash is long enough, resulting in large charge transfer, then there is less probability of having return strokes following it. The 32 current-recorded flashes contain a total of 156 return strokes, with an average multiplicity of 4.875. It is worth mentioning that during one decade, 1992–2001, the CN Tower current derivative measurement system only recorded 478 return strokes, demonstrating that the number of return strokes recorded at the tower within about 84 min is close to one third of those recorded at the tower during one decade. This finding clearly shows the great value and rarity of the presented extensive lightning current derivative data. Only one of the 32 current-recorded flashes is proved to be positive with a single return stroke. Based on current records, out of a total of 124 inter-stroke time intervals, 94% are found to be within 200 ms, with an overall inter-stroke time average of 68.1 ms. The maximum inter-stroke time recorded during this storm is 726.3 ms, the longest ever recorded at the CN Tower. Highlights: The paper provides an analysis of the most intense lightning storm ever recorded at the CN Tower. Based on video records, the tower was struck with 52 lightning flashes within about 84 min. Video analysis showed that all flashes were upward initiated. Storm's inter-flash time varied between 10.6 s and 274 s with an average of 98 s. Flash time duration varied between 0.1 s and 2.135 s with an average of 1.225 s. Time duration of initial-stage current varied between 0.1 s and 1.835 s with an average of 0.77 s. Only 32 out of the 52 flashes were recorded by the current measurement system, including 156 strokes. … (more)
- Is Part Of:
- Journal of atmospheric and solar-terrestrial physics. Volume 154(2017)
- Journal:
- Journal of atmospheric and solar-terrestrial physics
- Issue:
- Volume 154(2017)
- Issue Display:
- Volume 154, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 154
- Issue:
- 2017
- Issue Sort Value:
- 2017-0154-2017-0000
- Page Start:
- 195
- Page End:
- 206
- Publication Date:
- 2017-02
- Subjects:
- Tall-structure lightning -- Lightning current -- Inter-flash time -- Flash duration -- Initial-stage duration -- Flash multiplicity -- Return strokes -- Inter-stroke time
Geophysics -- Periodicals
Atmospheric physics -- Periodicals
Géophysique -- Périodiques
Météorologie physique -- Périodiques
Electronic journals
551.51 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13646826 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jastp.2016.05.002 ↗
- Languages:
- English
- ISSNs:
- 1364-6826
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4947.950000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1277.xml